beautypg.com

15 replacement of parts – Glow-worm Ultrapower sxi Range User Manual

Page 65

background image

65

13234

Diagram 15.22

15 Replacement of Parts

15.26 Filling Loop

For access, refer to section 15.1.
Refer to section 15.1 and drain the boiler domestic water

circuit.
Refer to diagram 12.3.
Undo the union nuts on the filling loop valve and the double

check inlet valve to remove the filling loop.
Fit new ‘O’ rings.
After replacing the filling loop open the cold-water isolation

valve and slowly open a hot water tap to remove air. Close the

hot water tap and check for any leaks.
IMPORTANT: To comply with the water regulations the

flexible hose must be disconnected from the double check

inlet valve - undo the nut and pull the flexible hose from

the valve.

15.27 Automatic Bypass Valve

For access, refer to section 15.1.
Refer to section 15.1 and drain the boiler primary circuit.
Refer to diagram 15.22.
Remove the retaining clip to remove the bypass valve.
Fit new ‘O’ rings.
Replace the bypass valve, refill, vent and pressurise the

boiler.
Adjust the bypass as described in commissioning, see section

12.8.

15.28 Pressure Reducing Valve

For access, refer to section 15.1.
Refer to diagram 15.23.
Slacken the three screws securing the pipe retaining bracket,

see diagram 8.3.
Undo the union connection at the isolation valve and then the

union nuts to remove the reduced pressure zone valve.
Fit new ‘O’ rings.

15.29 Safety Relief Valve

For access, refer to section 15.1.
Refer to diagram 15.23.
Undo the two nuts securing the safety relief valve pipe and

remove.
Loosen the grub screw to remove the safety relief valve.

15.30 Temperature and Pressure Relief Valve

For access, refer to section 15.1.
Refer to section 15.1 and drain the boiler hot water circuit.
Refer to diagram 15.24.
Undo the union nut on the right hand side of the valve and

disconnect pipe, unscrew the valve body to remove.
Apply the sealant supplied before replacing the relief valve.

13345

13334

TEMPERATURE AND

PRESSURE RELIEF

VALVE

UNION NUT

CYLINDER

TANK

BOILER / TANK MODULE

CONNECTIONS

Diagram 15.24

GRUB SCREW

6 bar SAFETY

RELIEF VALVE

3.5 bar

PRESSURE

REDUCING

VALVE

UNION NUTS

SAFETY

RELIEF

VALVE PIPE

Diagram 15.23