beautypg.com

11 electrical connection – Glow-worm Ultrapower sxi Range User Manual

Page 39

background image

39

11 Electrical Connection

13369

13460

13368

11.2 System Controls 24V

WARNING: UNDER NO CIRCUMSTANCES MUST

ANY MAINS VOLTAGE BE APPLIED TO ANY OF THE

TERMINALS ON THE 24V CONNECTION PLUG.
Connect the mains supply and system heating controls e.g.

room thermostat as diagram 11.4. External controls should be

fitted in accordance with the rules in force.
If fitting a proprietary programmer as part of the system

controls the internal central heating programmer will need to

be disabled as described in section 11.4. If fitting the Glow-

worm Climapro programmer the internal programmer will

automatically be disabled.

11.3 Mains Voltage System Controls

WARNING: UNDER NO CIRCUMSTANCES MUST

ANY MAINS VOLTAGE BE APPLIED TO ANY OF THE

TERMINALS ON THE 24V CONNECTION PLUG.
Connect mains supply and system controls as diagram 11.5.
External controls should be fitted in accordance with the rules

in force.
If fitting a proprietary programmer as part of the system

controls the internal central heating programmer will need to

be disabled as described in section 11.4. If fitting the Glow-

worm Climapro programmer the internal programmer will

automatically be disabled.

11.4 Disabling the internal CH Programmer

If fitting an external proprietary CH Programmer, it is

necessary to disable the Internal Programmer.

a) Press and hold the ‘mode’ button for 5 seconds. The

display will change to flashing ‘0’.

b) Use the ‘+’ or ‘-’ button to scroll to 96.

c) Press ‘MODE’ to confirm.

d) The display now shows a flashing ‘d. 0’ Use the ‘+’

or ‘-’ key to scroll to ‘d.92’.

e) Press ‘MODE’ to confirm.

f) The display now shows a flashing ‘3’ above the

‘d.92’.

g) Use the ‘+’ or ‘-’ button to change this value to ‘1’.

h) Press ‘MODE’ to confirm, ‘1’ stops flashing and is

saved.

i) Press and hold ‘MODE’ to exit.

The CH Programmer has now been disabled. The DHW

Programmer is still active. See the diagnostic menu

instructions in the Fault Finding section for further details.

11.5 Tank Thermistor

The tank thermistor should be connected between the boiler

and tank modules. The cable and connection plug from the

control box passes through a grommet on the base of the

boiler module to the connection on the LH side of the tank

module, see diagram 11.6.

11.6 Electrical Connections - Testing

Carry out preliminary electrical system checks as below:
1. Test insulation resistance to earth of mains cables.
2. Test the earth continuity and short circuit of cables.
3. Test the polarity of the mains.

GROMMET

BOILER MODULE

TANK MODULE

To Control Box

TANK THERMISTOR

CONNECTION

Diagram 11.6

Diagram 11.5

Diagram 11.4