RETAINING

BRACKET

INSIDE VIEW OF

CONTROL BOX

ELECTRICAL

CONNECTION

RETAINING

CLIP

UNION

NUT

PUMP

RETAINING

SCREW

TOP VIEW OF

CENTRAL HEATING PUMP

UNION

NUT

RETURN PIPE

15 Replacement of Parts

CONNECTION

CLIPS

HEATING

RETURN

HEATING

FLOW

HEAT EXCHANGER

Diagram 15.9

13327

Diagram 15.11

13342

Remove the two connection clips securing the flow and return

pipes to the heat exchanger, see diagram 15.9.
Move the pipes away from the heat exchanger.
Remove the four heat exchanger securing screws and

clamps, see diagram 15.8.
CAUTION: There will be water in the heat exchanger.
Remove the push fit condense pipe from the bottom of the

heat exchanger, see diagram 15.10.
Carefully remove the heat exchanger and disconnect the flue

overheat thermostat, see diagram 13.11.

13444

Diagram 15.10

HEAT EXCHANGER CONDENSATE

CONNECTION (push-fit)