11 Electrical Connection
11.1 Electrical Connection
Take the previously laid electrical cable and route along the
left hand side of the tank module through the two grommets
and the cable ties and across to the installers interface as
shown in diagram 11.1.
Take the electrical cartridge from the loose items pack.
Remove the securing screw to open the cartridge.
NOTE: There are two screws supplied loose in the electrical
cartridge, these will be required to secure the cartridge into
the electrical interface housing.
Slacken the two screws of the cable strain relief in the
electrical cartridge, see diagram 11.2.
Route the mains supply and systems cables through the
strain relief and connect to the relevant plug dependant upon
your choice of system controls, refer to relevant sections 11.2
and 11.3.
Initially, if system controls are not available then fit a wire
link between “L” and “R”, this will allow the boiler to run
continuously on heating.
Fit electrical cartridge into the interface housing on completion
of the wiring, see diagram 11.3.
Secure with the two cartridge retaining screws provided in the
cartridge body.
Diagram 11.2
RETAINING
SCREW
(2 OFF)
ELECTRICAL
CARTRIDGE
13306
Diagram 11.3