beautypg.com

15 replacement of parts – Glow-worm Ultrapower sxi Range User Manual

Page 58

background image

58

15 Replacement of Parts

15.9 Burner

For access, refer to section 15.1.
Refer to section 13.4 for removal of the fan, gas valve and

burner assembly.
Remove the four screws that secure the burner, see diagram

13.12.
NOTE: THE BURNER WILL REQUIRE A NEW GASKET

WHEN REFITTED.

15.10 Front Insulation

For access, refer to section 15.1.
Refer to section 13.4 for removal of the fan, gas valve and

burner assembly.
Remove spark electrode, see section 15.6.
Remove burner as described in the appropriate section of

15.9 and withdraw the insulation, see diagram 13.12.
NOTE: THE BURNER WILL REQUIRE A NEW GASKET

WHEN REFITTED.

15.11 Rear Insulation

For access, refer to section 15.1.
Refer to section 13.4 for removal of the fan, gas valve and

burner assembly.
Remove securing screw and washer in the centre of the

insulation and withdraw insulation, see diagram 15.5.

15.12 Viewing Window

For access, refer to section 15.1.
Refer to diagram 15.6.
Remove circlip.
Remove steel washer.
Remove glass.
Remove fibre washer.

FIBRE WASHER

GLASS

STEEL WASHER

CIRCLIP

Diagram 15.6

13278

Diagram 15.5

13407

HEAT EXCHANGER

REAR

INSULATION

WASHER

SECURING

SCREW