beautypg.com

Glow-worm Ultrapower sxi Range User Manual

Page 25

background image

25

10.2 Horizontal Telescopic Flue

Refer to diagram 10.2 for kit contents.

10.3 REAR Flue

If a wall thickness is between 233mm min. to 522mm max.

then the flue can be used without extensions.

With the flue elbow temporarily fitted, measure the distance

from the outside wall to the butt joint, see diagram

10.4

. If

the measurement ‘Y’ exceeds 522mm, then the appropriate

length of extension pipe is required.
If the dimension is less than 320mm DO NOT cut the flue, it

can project to a maximum of 600mm, if this is not desirable

then a Standard flue MUST be used and cut to length.

10.4 SIDE Flue

With the flue elbow temporarily fitted, measure the distance

from the outside wall to the butt joint, see diagram 9.6. If the

measurement ‘Y’ exceeds LH 204mm, RH 417mm, then the

appropriate length of extension pipe is required.
If the dimension is less than 320mm DO NOT cut the flue, it

can project to a maximum of 600mm, if this is not desirable

then a Standard flue MUST be used and cut to length.

Diagram 10.4

Diagram 10.6

12979

10 Telescopic Flue - Length, Preparation and Installation

Diagram 10.5

13224

13295