beautypg.com

10 plume management kit, 11 electrical connection – Glow-worm Ultrapower sxi Range User Manual

Page 37

background image

37

10 Plume Management Kit

10.13 Plume Management Kit

The Plume Management Kit: Part No. A2044100 (white) or

A2044000 (black) can be used to overcome many site issues.
The Plume Management Kit will fit to the Top Horizontal

Telescopic, Rear Horizontal Telescopic and Standard

Horizontal Flue. This enables the flue products to exhaust

further away from the boiler, thereby reducing the impact

of pluming. The flue air inlet can be sited closer to doors,

opening windows and air bricks, see diagram 10.30.
The maximum length of the Plume Management Kit must NOT

exceed 6m with a horizontal concentric flue length of 2m max.
For each 90

o

bend or 2 x 45

o

bends the maximum length of the

Plume Management Kit must be reduced by 1m.
For more information contact Glow-worm, refer to page 2.
The Plume Management Kit is supplied with installation

instructions.
Refer to BS5546 or BS6798 for advice on disposal of boiler

condensate.

Diagram 10.30

12997

WARNING: This appliance must be earthed.
● This appliance must be wired in accordance with these

instructions. Any fault arising from incorrect wiring cannot be

put right under the terms of the Glow-worm guarantee.
● All system components must be of an approved type.
Electrical components have been tested to meet the

equivalent requirements of the BEAB.
● Do not interrupt the mains supply with a time switch or

programmer.
● Connection of the whole electrical system and any heating

system controls to the electrical supply must be through a

common isolator.
● Isolation should preferably be by a double pole switched

fused spur box having a minimum contact separation of

3mm on each pole. The fused spur box should be readily

accessible and preferably adjacent to the boiler. It should be

identified as to its use.
● A fused three pin plug and shuttered socket outlet may be

used instead of a fused spur box provided that:
a) They are not used in a room containing a fixed bath or

shower.
b) Both the plug and socket comply with the current issue of

BS1363.

11 Electrical Connection

Immersion Heater

- the thermostatically controlled

immersion heater with manual reset is fitted to the cylinder

as a back up for domestic hot water in the event of the boiler

being inoperable, it MUST be wired separately from the boiler

electrical connections.
The heater should be wired through a double-pole switch or

controller having a minimum contact separation of 3mm on

each pole. Use a cable size of at least 1.5sq. mm flexible

cable, 85 deg.C rubber insulated HOFR sheathed to comply

with BS6141 Table 8 and must be fully earthed.