Jt20 operator’s manual – Ditch Witch JT20 User Manual
Page 69
Prepare - 68
JT20 Operator’s Manual
Plan Bore Path
CMW
®
Pipe-By-Pipe Bend Limits
Pipe
(C)
Forward (B)
Deflection (A)
Pipe
(C)
Forward (B)
Deflection (A)
1
10 ft 0 in (3.0 m)
0 ft 5 in (0.1 m)
12
103 ft 8 in (31.6 m)
51 ft 7 in (15.7 m)
2
19 ft 11 in (6.1 m)
1 ft 6 in (0.5 m)
13
109 ft 5 in (33.3 m)
59 ft 9 in (18.2 m)
3
29 ft 9 in (9.1 m)
3 ft 5 in (1.1 m)
14
1114 ft 6 in (34.9 m)
68 ft 5 in (20.8 m)
4
39 ft 4 in (12.0 m)
6 ft 1 in (1.9 m)
15
118 ft 10 in (36.2 m)
77 ft 4 in (23.6 m)
5
48 ft 9 in (14.9 m)
9 ft 6 in (2.9 m)
16
122 ft 7 in (37.4 m)
86 ft 8 in (26.4 m)
6
57 ft 11 in (17.6 m)
13 ft 7 in (4.1 m)
17
125 ft 6 in (38.3 m)
96 ft 2 in (29.3 m)
7
66 ft 8 in (20.3 m)
18 ft 5 in (5.6 m)
18
127 ft 9 in (38.9 m)
105 ft 11 in (32.3 m)
8
75 ft 1 in (22.9 m)
23 ft 10 in (7.3 m)
19
129 ft 3 in (39.4 m)
115 ft 10 in (35.3 m)
9
83 ft 0 in (25.3 m)
29 ft 11 in (9.1 m)
20
129 ft 11 in (39.6 m)
125 ft 10 in (38.3 m)
10
90 ft 5 in (27.6 m)
36 ft 7 in (11.2 m)
20.4
130 ft 0 in (39.6 m)
130 ft 0 in (39.6 m)
11
97 ft 4 in (29.7 m)
43 ft 10 in (13.4 m)
Pipe 10 is illustrated.