Esid, Jt20 operator’s manual – Ditch Witch JT20 User Manual
Page 56
JT20 Operator’s Manual
Controls - 55
ESID
CMW
®
ESID
1.
Alphanumeric display
2.
Strike indicator
3.
Alarm interrupt button
4.
Voltage problem indicator
5.
Current problem indicator
6.
OK indicator
7.
Electrical power supply indicator
8.
Self test button
Item
Description
Notes
1.
Alphanumeric display
Displays amount of current
and voltage being detected
as a percentage of strike
condition.
The line with the “V” shows
voltage reading and the line
with the “A” shows current
reading.
2.
Strike indicator
Red lights come on as values
in display increase.
Light in triangle represents
strike warning condition and
will trigger alarm(s) and
strobe(s).
IMPORTANT: System can go
from one or two lights to an
electric strike immediately.
If system is activated, assume a strike
has occurred.
NOTICE: The ESID does not indicate
proximity to electric lines. System will
activate only when voltage and/or
amperage detected at the drilling unit
are above threshold minimum limits.
j07om042h.eps
1
2
3
4
5
6
7
8