beautypg.com

Dillon Precision SL 900 User Manual

Page 26

background image

1. Using a Dillon bin (#17125) or box, gather up

to 80 empty, fired hulls. Fig. 37

2. Always examine the hulls for rocks, dirt, mud or

other cases that may get stuck inside. Also look for

hulls that may appear stepped on or flattened. Go

ahead and squeeze them round again so they won’t

get stuck in the casefeed tube (#20536). Fig. 38

3. Pour the hulls into the casefeeder and turn the

unit on.

4. The casefeeder will run until the casefeed tube

(#20536) has filled, then shuts off automatically when

a hull trips the microswitch. Fig. 39 Insure that the

casefeed tube is fully seated into its clamp.

5. Get one box of new shotshell primers.

6. Slide the cardboard jacket back, exposing only

half of the first row of primers. Fig. 40

7. Turn the box of primers over.

8. Place the leading edge of the primer tray into

the machine’s primer feedplate (#16711).

Fig. 41

9. Slide the cardboard jacket off. Helpful hint – as

you slide the cardboard jacket off, place your left-

hand index finger on the primer tray and press down

as you slide the jacket off. Fig. 42

Fig. 37

Fig. 38

Fig. 41

Fig. 42

Microswitch

Fig. 40

Fig. 39

26

SL 900, May 2007 5/21/07 11:51 AM Page 26