This test is an automatic test. Upon entry, this test will continually ru
n
the drawbridge up and
down (w
i
th small pauses in between when a drawbridge up/down switch edge is detected
)
while
the test is running. To stop the drawbr
i
dge motor from running during this test, press the Enter
button. To re-start the drawbridge motor, press the Enter button aga
i
n.
This test is useful for clearing "Drawbr
i
dge Down Switch Bad" and
"
Drawbridge Up Switch Bad"
errors that may appear in the test report. If errors exist, they will be shown on the bottom line of
the d
i
splay
.
The error(s) are cleared when the drawbridge completes two consecutive successful
operations to either open or close the drawbr
i
dge
.
Dur
i
ng this test, the diagnostic test buttons on the coin door act as follows:
Escape: This button returns to the previous menu.
Ente
r
: This button toggles the state of the test from Running to Stopped
,
or from Stopped to
Running.
This test is used to verify proper operation of the castle gate and the exploding castle.
It
exercises the moat entrance, castle gate
,
and castle lock switches
,
along with the castle gate and
the exploding castle.
To verify castle gate operation in "Castle Gate Mode
"
,
press the Up or Down buttons unt
i
l
the message
"
Tes
t
Mode
:
At Castle Gate
"
appears on the second line of the display. The
castle gate should set itself to the Down position when this mode is entered. Roll a ball
at the castle gate. A sound is made as the ball passes through the switches, and the
state of the switches is updated in the display. The ball should tr
i
gger the moat entrance
switch (M.EN)
,
followed by the castle gate switch (C.GT)
,
followed by
t
he moat entrance
switch (M.EN) again, and the test should
r
eport
"
TEST PASSED - PRESS ENTER" on
the bottom line of the display
.
Any other result indicates a problem with either the
switches
,
or the castle gate
,
or both. To re-tes
t
, press t
h
e Ente
r
button.
T.18
DRAWBRIDGE TEST
T.19 CASTLE GATE TEST
Th
i
s test is used to ve
r
i
fy prope
r
ope
r
ation of the drawbridge. It exercises the drawbr
i
dge mo
t
o
r
,
and the drawbridge pos
i
tion switches.
When this test is entered, the test attempts to lower the drawbridge in order to provide access to
the castle gate.
The test does this by activating the drawbridge motor and waiting for the
drawbridge
"
down
"
switch to close.
I
f
t
he test is unable to position the drawbr
i
dge in
t
his manner,
the message "DRAWBRIDGE ERROR - SEE T.18" will be shown on the bottom line of the
display
.
If this occurs, it will be necessary to repair the drawbridge (use T
.
18 to verify proper
drawbridge operation after it is repa
i
red)
.
This test wi
ll
not opera
t
e at
all if it cannot position the
drawbridge properly
.
This test has two modes of operation:
Castle Gate Mode: This mode is used to verify that the ball is able to strike the castle
gate
.
This is use
fu
l
tor clear
i
ng
"
Castle Gate Stuck Open
"
errors that may appear in the
test report. If the error exists, it will be shown on the bottom line of the display.
"Castle Gate Stuck Open" errors can be cleared in "Castl
e
Gate Mode" by repeatedly
testing the castle gate (the Enter button must be pressed at the end of each test)
.
The
test w
i
ll clear this error when
there have been two consecutive successful castle gate
tests in this mode.
Castle Mode: This mode is used to verify that the ball
i
s able to pass through the
cast
l
e
gate and into the castle lock area
.
This is useful for clear
i
ng any
"
Castle
Gate
Stuck Closed" errors that may appear in the test report. If the error exists, it
will be shown on the bottom line o
f
the display.
1-2