Troubleshooting metadata problems, Outputting metadata, 4 troubleshooting metadata problems – Dolby Laboratories DP570 User Manual
Page 41: 5 outputting metadata, Figure 4-2
Using the DP570 Features
Troubleshooting Metadata Problems
Dolby
®
DP570 Multichannel Audio Tool User’s Manual
29
Figure 4-2
Adding a Second Program
4.4
Troubleshooting Metadata Problems
The DP570 has several status indicators to help troubleshoot metadata‐related problems.
The front‐panel status display shows the metadata source as External if any metadata
source is set to external.
Metadata Input
indicators on both the DP570 front panel and in the DolbyRemote 570
software provide status information. The indicators are green any time a valid metadata
signal is present, whether or not it is being used. They turn red only when an external port
is in use and there is a problem with the metadata signal.
The Metadata Params submenu under either the Setup or status menu on the
front‐panel display can also be used to determine the current source for a parameter and
its current value.
4.5
Outputting Metadata
You can choose to send metadata from the DP570 to downstream devices using the
Metadata Output
connector on the rear panel. The frame rate for output metadata is set by
the received video reference signal and is locked to the beginning of the video frame.
Note: If the DP570 is using external metadata and there is a temporary error in the
metadata stream, the unit continues to use the last valid metadata values. When
the error clears, the DP570 resumes using the stream from the external port.
DP572
DP570
DP571
Digital
Output
Router
Output
Metadata Out
Digital
Input
Metadata
In
Metadata
In
Metadata
Out
Digital
Input
Metadata Adjustment
• Change Program Config
to 5.1+2 (internal source)
• Set parameters for new
two-channel program
D 563
P
In
Out
6
5.1
5.1+2
8
2