INSTALLATION
INSTALLATION
9.4.4 Pitting powfir table
Installing the power cable
160________
A
''k
30.
--------- -
1
» Prepare the power cable.
»Use the plastic cap as an installation aid.
9.4.5 Inserting the twin nipples
9.4.6 Preparing the water connection
»Secure the lee and cross-piece to the twin nipples with flat
packing.
»Thoroughly flush the cold water supply line.
• I Three-way shut-off valve
11 Never use the three-way shut-off valve to reduce the
flow rate: it is only designed to shut off a circuit.
1
Tee
2
Cross-piece
9.4.7 Fitting the sieve
» Fit the sieve provided in the cold water inlet of the appliance.
Vl sieve
1-1 The sieve must always be fitted for the function of the
appliance to be guaranteed. If an appliance is being
replaced during installation, ensure (hat a sieve is
available.
Fitting the sieve
t/i
_i
19
9.4.8 Installing (he DMB flow limiter
»Position the Flew limiter provided in the cold water inlet of the
appliance.
A second flow limiter is provided with the DHB-E 18/21/24 SLi.
Install the Flew limiter with an output corresponding to that of
the appliance. The colour of the flow limiter is given in the table
"Specification".
9.4.9 Mounting the appliance
The cable grommet pointing towards the wall may hinder the
mounting of the appliance close to the wall. To prevent such
problems, it is advisable to briefly press the cable grommet
DHB-E ... SLi electronic |