Table 3 — option packages, Factory-installed options, Table 4 — condensing unit specifications – Carrier 38E User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Factory-Installed Options
— Any condensing unit
or heat pump listed in Tables 1 and 2 may be ordered as
Basic or in one of 3 factory-option packages. Package
designations are included in model number (excluding
Basic). Example: 38EN0243015A/. SM designates this
unit as sheet metal option package. Option package
designations are shown in Table 3.
Table 3 — Option Packages
Basic
38EH,ES
Standard unit with no added options.
Sheet Metal Option (SM)
Same unit as Basic except with addition
of louvered inlet casing.
Deluxe Option (DL)
Same unit as (SM) except for addition ■
of start assist components on single
phase units, crankcase heater, high-
and low-pressure switches, and
accumulator.
Custom Deluxe Option (CD)
Same unit as (DL) except for addition of
sound shield around compressor, and
Time Guard II device.
Basic
38EN
Standard unit with no added options.
Sheet Metal Option (SM)
Same unit as Basic except for addition
of louvered inlet casing.
Basic
38QH,QS
Standard unit with no added options.
Sheet Metal Option (SM)
Same unit as Basic except for addition
of louvered inlet casing.
Deluxe Option (DL)
Same unit as (SM) except for addition
of start assist components on single
phase units, high-pressu.re switch, and
Service Sentry device.
Custom Deluxe Option (CD)
Same unit as (DL) except for addition
of sound shield around compressor and
Time Guard II device.
Basic
38QN
Standard unit with no added options.
Sheet Metal Option (SM)
Same unit as Basic, except for addition
of louvered inlet casing.
Table 4 — Condensing Unit Specifications
OUTDOOR
UNIT
MODEL NO.
38-
ORIGINAL
COMPRESSOR
REPLACEMENT
COMPRESSOR
OIL CHARGE
REFRIG
CHARGE*
MODEL
MODEL
Initial
Recharge
(R-22)
EH-
015301
REZ3-0125
50QT662300
24
20 ■
■ 6.2
018301
AB5515H
50SR661301
32
30
6.3
024301
MD2315GG
MD2364GE
46
44
5.6
030301
MD3215GG
MD3264GE
46
44
7.3
036301
AV5535E
50SR661336
54
50
7.4
042301
AV5542E
50SR661300
54
50
7.1
048321
AV5546H
50SR661331
54
50
8.9
060301
PC6016BD
PC6066ED
76
72
'12.7
EN-
015310
AK8515E
51D2661300
17
15
, 3 . 2
018310
RES3-0175-PFV
38EA662301
24
20
3.7
024310
H21B243ABC
38EN663307
40
37
3.8
030300
H21A313ABCA
38EN663302
40
37
5.6
D30320
MD3215GG
MD3264GE
46
44
. 6.7
036320
H21A363ABCA
38EN663303
50
47
5.8'
042300
H21A463ABCA
■ 38EN663304
50
47
7.2
048300
PC5316BD
PC5366HD
76 .
72
7.6
060300
PC6716AG
PC6766HG
76
72
9.5
060310
PC6716AG
PC6766HG
76
72
12.5
030500
H21A313DBD
38EN663501
40
37
5.5
036500
H21A373DBD
38EN663502
50
47
5.8
042500
H21A463DBD
38EN663500
50
47
7.2
048500
PY5316AD
See Note t
76
72
7.6
060500
PY6716AF
See Note t
76
72
9.6
060510
PY6716AF
See Note $
76
72
12.5
036600
H21A373DBE
38 EN 663600
50
47 .
5.8
042600
A21A463DBE
38EN663601
50
47
7.2
048600
PH5316AD
PH5366HD
76
72
7.6
060600
PH6716AF
PH6766HF
76
72
9.6
060610
PH6716AF
PH6766HF
76
72
12.5
ES-
018
AB5515H
50SR661301
32
28
7.20
024
CRC1-0175-PFV
38VH660303
55
51
7.40
030
H23A263ABCA
50SR661333
50
46
6.50
036
CRH3-0275-PFV
51HK660304
55
51
7.50
042
CRK3-0325-PFV
48GH 662302
55
51
7.80
048
AV5546H
50SR661331
54
50
12.50
060
—
—
’Factory refrigerant charge is adequate when indoor unit and outdoor unit are the same size
and are connected with 25 ft or less of field tubing of recommended size or Carrier accessory
tubing. For tubing requirements beyond 50ft, consult Carrier distributor.
NOTE: Originally an extended voltage compressor.
Select replacement compressor for voltage required:
tPF5366HD (200-3-60), PG5366HD (230-3-60).
tPF6766HF (200-3-60), PG6766HF (230-3-60).
H-R