Factory-Installed Options

— Any condensing unit

or heat pump listed in Tables 1 and 2 may be ordered as

Basic or in one of 3 factory-option packages. Package

designations are included in model number (excluding

Basic). Example: 38EN0243015A/. SM designates this

unit as sheet metal option package. Option package
designations are shown in Table 3.

Table 3 — Option Packages

Basic

38EH,ES

Standard unit with no added options.

Sheet Metal Option (SM)

Same unit as Basic except with addition
of louvered inlet casing.

Deluxe Option (DL)

Same unit as (SM) except for addition ■

of start assist components on single­

phase units, crankcase heater, high-
and low-pressure switches, and
accumulator.

Custom Deluxe Option (CD)

Same unit as (DL) except for addition of
sound shield around compressor, and
Time Guard II device.

Basic

38EN

Standard unit with no added options.

Sheet Metal Option (SM)

Same unit as Basic except for addition
of louvered inlet casing.

Basic

38QH,QS

Standard unit with no added options.

Sheet Metal Option (SM)

Same unit as Basic except for addition
of louvered inlet casing.

Deluxe Option (DL)

Same unit as (SM) except for addition
of start assist components on single­
phase units, high-pressu.re switch, and
Service Sentry device.

Custom Deluxe Option (CD)

Same unit as (DL) except for addition
of sound shield around compressor and
Time Guard II device.

Basic

38QN

Standard unit with no added options.

Sheet Metal Option (SM)

Same unit as Basic, except for addition
of louvered inlet casing.

Table 4 — Condensing Unit Specifications

OUTDOOR

UNIT

MODEL NO.

38-

ORIGINAL

COMPRESSOR

REPLACEMENT

COMPRESSOR

OIL CHARGE

REFRIG

CHARGE*

MODEL

MODEL

Initial

Recharge

(R-22)

EH-

015301

REZ3-0125

50QT662300

24

20 ■

■ 6.2

018301

AB5515H

50SR661301

32

30

6.3

024301

MD2315GG

MD2364GE

46

44

5.6

030301

MD3215GG

MD3264GE

46

44

7.3

036301

AV5535E

50SR661336

54

50

7.4

042301

AV5542E

50SR661300

54

50

7.1

048321

AV5546H

50SR661331

54

50

8.9

060301

PC6016BD

PC6066ED

76

72

'12.7

EN-

015310

AK8515E

51D2661300

17

15

, 3 . 2

018310

RES3-0175-PFV

38EA662301

24

20

3.7

024310

H21B243ABC

38EN663307

40

37

3.8

030300

H21A313ABCA

38EN663302

40

37

5.6

D30320

MD3215GG

MD3264GE

46

44

. 6.7

036320

H21A363ABCA

38EN663303

50

47

5.8'

042300

H21A463ABCA

■ 38EN663304

50

47

7.2

048300

PC5316BD

PC5366HD

76 .

72

7.6

060300

PC6716AG

PC6766HG

76

72

9.5

060310

PC6716AG

PC6766HG

76

72

12.5

030500

H21A313DBD

38EN663501

40

37

5.5

036500

H21A373DBD

38EN663502

50

47

5.8

042500

H21A463DBD

38EN663500

50

47

7.2

048500

PY5316AD

See Note t

76

72

7.6

060500

PY6716AF

See Note t

76

72

9.6

060510

PY6716AF

See Note $

76

72

12.5

036600

H21A373DBE

38 EN 663600

50

47 .

5.8

042600

A21A463DBE

38EN663601

50

47

7.2

048600

PH5316AD

PH5366HD

76

72

7.6

060600

PH6716AF

PH6766HF

76

72

9.6

060610

PH6716AF

PH6766HF

76

72

12.5

ES-

018

AB5515H

50SR661301

32

28

7.20

024

CRC1-0175-PFV

38VH660303

55

51

7.40

030

H23A263ABCA

50SR661333

50

46

6.50

036

CRH3-0275-PFV

51HK660304

55

51

7.50

042

CRK3-0325-PFV

48GH 662302

55

51

7.80

048

AV5546H

50SR661331

54

50

12.50

060

’Factory refrigerant charge is adequate when indoor unit and outdoor unit are the same size

and are connected with 25 ft or less of field tubing of recommended size or Carrier accessory
tubing. For tubing requirements beyond 50ft, consult Carrier distributor.

NOTE: Originally an extended voltage compressor.

Select replacement compressor for voltage required:
tPF5366HD (200-3-60), PG5366HD (230-3-60).
tPF6766HF (200-3-60), PG6766HF (230-3-60).

H-R