7.3  

Set IP Utility 

The Set IP utility allows the user to configure the network settings on the JSD‐100.   
 

 Connect  the  host  computer  to  the  USB  port  on  the  front  of 

the  JSD‐100.    The  JSD‐100  should  appear  under  the  USB 
Device List.  It is identified by which USB port it is connected 
to on the host computer. Click the JSD‐100 on the found list. 

 Fill  in  the  IP  address,  subnet  mask,  and  gateway  as  dotted 

decimal values.  Press “Set IP” to save the values in the JSD‐
100. 

 Fill in the network hostname for the JSD‐100.  The hostname 

can  be  up  to  15  characters  long  and  cannot  contain  spaces.  
The  hostname  will  be  converted  to  upper  case  before  being 
saved.  Press “Set Name” to save the value to the JSD‐100. 
 

7.4 

JSD‐100 Configuration 

The JSD‐100 is configured using the graphical user interface (Shown in start menu as:  JSD‐100 Cinema Processor).  
The GUI may connect to the JSD‐100 over USB, RS‐232, or Ethernet.  In most installations, configuration is done 
over USB.  With USB, it is very clear which JSD‐100 you are configuring (the one that the USB cable is plugged in 
to).  Note that you can import existing JSD‐80 settings to the JSD‐100.   See File Management – Open, below.  
 
The GUI and the JSD‐100 provide two sets of controls and two displays. For example, you can change the format on 
either the JSD‐100 unit or on the GUI and both will reflect the new value.  If you open a configuration file when 
connected to the JSD‐100, all the settings in that configuration file are sent to the JSD‐100.  When you connect to a 
JSD‐100, all the configuration settings in that unit are loaded into the GUI.  It is quite possible to operate the GUI 
and  create  configuration  files  without  the  JSD‐100  being  connected.    Make  sure  the  new  file  is  saved  before 
connecting the JSD‐100 since the connection will cause the current values in the JSD‐100 to be overwritten with 
the values in the JSD‐100. When the JSD‐100 is connected to the GUI and a new configuration file opened, that 
configuration data is copied out to the connected JSD‐100. 
 

When the GUI is started, the “Overview Screen” will be visible. This screen can 
show the status of multiple JSD‐100 systems on a network.  The title bar shows 
the  theater  name  and  the  screen  number  for  that  particular  JSD‐100.  Click 
“Screen 1”to bring up the details of the first (and only, at this point) JSD‐100.  

 

Click  “Comm  Settings”  and  then  the  “USB”  tab.    Make  sure  “Connect  to  first 
available  USB  device”  is  checked  and  then  press  OK.  Press  the  “Connect” 
button to connect to the JSD‐100.  Current settings will be downloaded from 
the JSD‐100 and displayed on the GUI.  Detailed below are the several buttons 
that are visible along the top of the GUI. 
 
File Management 
This  group  of  buttons  detailed  below  deals  with  loading  and  saving  configuration  files  from  the  host  computer. 
Configuration files are located in the My Documents\USL\JSD‐100 directory. 
 
New.    Pressing  “New”  creates  a  new  configuration  file  with  all  settings  at  their  default  values.  It  does  not 

change the settings in the JSD‐100 or in the GUI view of the JSD‐100. You can use this as a starting point for 
configuring a new system (you could also use open Default.j100, as described below).  You will be presented 
with a “save as” dialog asking you to name the new configuration file.  

Open.  Pressing “Open” allows you to load an existing configuration fie.  Use Default.j100 to load the factory 

defaults.  You can then revise the settings and save them under another filename. Note that you may specify