beautypg.com

Isobus job computer : ic18 sprayer, Test output – TeeJet IC18 SPRAYER JOB COMPUTER User Manual

Page 46

background image

40

www.teejet.com

ISOBUS Job Computer : IC18 Sprayer

OVER

VIE
W

SE

TUP

APPENDIX

GE

TTING ST

AR

TED

OPER

ATION

Test Output

Figure 3-36: Test Output

Test Output sets the Liquid Valve PWM Dutycycle

percentage as well as if Liquid Valve Direction, Master

Valve, Fill Valve and Section Valves 1-9 are on or off.

Liquid Valve PWM Dutycycle

Liquid Valve PWM Dutycycle is used to test the regulating

valve at different percentages of duty cycle.

• To set the Liquid Valve PWM Dutycycle, use the

number pad or slide bar.

Liquid Valve Direction

Liquid Valve Direction is used to verify the option of the

Liquid valve direction is correct to a specific duty cycle.

• Set the Liquid Valve PWM dutycycle to the

percentage to be tested.

• Change the Liquid valve direction to "on" and the

liquid valve will open at the specific dutycycle.

• Change it back to off and the valve will close.

Master Valve

Master Valve is used to test if the Master Valve is

operating correctly. If you change the setting to "on", the

valve will open, change it to "off" and the valve will close.

• To set the Master Valve, select an option from the

drop down menu or use the UP/DOWN ARROWS to

highlight the option.

Section Valves

Section Valves is used to test if the section Valve is operating correctly. If you change the setting to "on", the

valve will open, change it to "off" and the valve will close.

• To set the Section Valves, select an option from the drop down menu or use the UP/DOWN ARROWS to

highlight the option.