Alarm Configurations
Figure 3-27: Alarm Configurations
Alarm Configurations establishes alarms on or off as well
as sets their trigger level.
CAN Speed Source Timeout
CAN Speed Source Timeout establishes how long the
system can operate after the CAN speed source input is
lost before the alarm is triggered.
• To select the CAN Speed Source Timeout time, use
the number pad or slide bar.
Active Trip Count Information
Active Trip Count Information sets the associated alarm
to on or off. This alarm is only displayed at powered up. It
tells the user which trip counter is active.
• To select the Active Trip Count Information mode, select an option from the drop down menu or use the UP/
DOWN ARROWS to highlight the option.
Tank Content Minimum
Tank Content Minimum establishes the minimum volume level at which an alarm will sound. Without a Tank
Sensor, the minimum is determined by calculating the difference between the established actual tank content
volume and the calculated applied content volume. With a Tank Sensor, the minimum is directly related to the
sensor reading.
• To select the minimum volume, use the number pad or slide bar.