beautypg.com

Isobus job computer : ic18 sprayer, Filling – TeeJet IC18 SPRAYER JOB COMPUTER User Manual

Page 30

background image

24

www.teejet.com

ISOBUS Job Computer : IC18 Sprayer

OVER

VIE
W

SE

TUP

APPENDIX

GE

TTING ST

AR

TED

OPER

ATION

Filling

Filling establishes the amount of material remaining in the tank and the density of that material.
Different options will be available depending on if a tank sensor is installed.
NOTE: The size of the tank is established in the OEM menu. This is the number that will repopulate when the Full

Tank Key is pressed.

Figure 3-14: Filling

Actual Content

Actual Content displays the current volume of content in

the tank. The volume can be manually adjusted.

• To adjust the volume, use the number pad or slide

bar.

NOTE: When a tank sensor is active, the actual content

can not be changed manually.

Density

Density establishes the density of the material being

applied. It can be set to either “fertilizer” or “water”.

• To select the Density, select an option from the drop

down menu or use the UP/DOWN ARROWS to

highlight the option.

NOTE: If “Fertilizer” is selected, a Density Factor option appears.

Density Factor

Density Factor establishes the weight per volume setting based on the type of fertilizer being used.

• To select the Density Factor, use the number pad or slide bar.

The fertilizer’s ability to flow is affected by a number of factors. These factors may vary with each batch and it may

change due to weather (humidity, etc.). In order to accommodate for this, the job computer uses a density factor

to compensate for the nature of the applied fertilizer.

Full Tank

Full Tank returns the Actual Content volume value to the maximum volume of the tank

• To reset the Actual Content value, press the FULL TANK KEY .