Isobus job computer : ic18 sprayer, Filling – TeeJet IC18 SPRAYER JOB COMPUTER User Manual
Page 30
![background image](/manuals/713544/30/background.png)
24
www.teejet.com
ISOBUS Job Computer : IC18 Sprayer
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
Filling
Filling establishes the amount of material remaining in the tank and the density of that material.
Different options will be available depending on if a tank sensor is installed.
NOTE: The size of the tank is established in the OEM menu. This is the number that will repopulate when the Full
Tank Key is pressed.
Figure 3-14: Filling
Actual Content
Actual Content displays the current volume of content in
the tank. The volume can be manually adjusted.
• To adjust the volume, use the number pad or slide
bar.
NOTE: When a tank sensor is active, the actual content
can not be changed manually.
Density
Density establishes the density of the material being
applied. It can be set to either “fertilizer” or “water”.
• To select the Density, select an option from the drop
down menu or use the UP/DOWN ARROWS to
highlight the option.
NOTE: If “Fertilizer” is selected, a Density Factor option appears.
Density Factor
Density Factor establishes the weight per volume setting based on the type of fertilizer being used.
• To select the Density Factor, use the number pad or slide bar.
The fertilizer’s ability to flow is affected by a number of factors. These factors may vary with each batch and it may
change due to weather (humidity, etc.). In order to accommodate for this, the job computer uses a density factor
to compensate for the nature of the applied fertilizer.
Full Tank
Full Tank returns the Actual Content volume value to the maximum volume of the tank
• To reset the Actual Content value, press the FULL TANK KEY .