25
98-05204 R1 US
ISOBUS Job Computer : IC18 Sprayer
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
Operation
Figure 3-15: Operation
Figure 3-16: Step % Increase/Decrease
C n t 5
5 . 0
2 8 3
4 0 7 0 g a l
2 8
p s i
1 . 1 4 a c
+ 5 %
1 3 11
G PA
m p h
Operation establishes Application Rate Step, Speed
Source and Simulated Speed.
Application Rate Step
Application Rate Step is the percent of increase/decrease
“boost” of the active application rate at which the product
is being applied.
• To select the percentage, use the number pad or
slide bar.
Speed Source
Speed Source selects whether to base the machine’s
speed on input from the CAN, an Implement or a
Simulated source. Selecting “Implement” will allow for
the configuration of pulses per 300 feet / 100 meters.
Selecting “Simulated” will allow for simulated speed to be
entered using the “Edit Value” option. Selecting “CAN”
allows for speed being supplied by the ISOBUS CAN
(usually from the TECU) to be used.
• To select the Speed Source, select an option
from the drop down menu or use the UP/DOWN
ARROWS to highlight the option.
NOTE: If “Implement” is selected, refer to the Calibrations
section for further instructions.
Simulated Speed
Simulated Speed establishes a speed to be used when
using the Simulated Speed source.
• To select the Simulated Speed, use the number pad or slide bar.