26

www.teejet.com

ISOBUS Job Computer : IC18 Sprayer

OVER

VIE
W

SE

TUP

APPENDIX

GE

TTING ST

AR

TED

OPER

ATION

Implement Parameters

Figure 3-17: Implement parameters

Figure 3-18: Section Width

Implement Parameters establishes the following:

►Section Width – sets the spraying width during

application.

►Nozzle Preset Setup – where up to five (5) sets of

nozzle options can be established to set the nozzle

type, size, low/high pressure limit, reference flow and

reference pressure.

►Regulation Parameters – where adjustments to the

valve calibration, nozzle spacing and regulations mode

can be established.

Section Width

Section Width sets the spraying width during application.

Boom Section Width

Section Width establishes the boom sections widths for

each boom section.
NOTE: The number of boom sections available is set on

the Implement Parameters screen in the OEM

section.

• To select the Boom Section Width, use the number

pad or slide bar.

When the section widths are changed, power must be

cycled in order to update the TASC Controller on the VT.

One-Touch Equal Widths

One-Touch Equal Widths sets all boom section widths to

the value set for #1 Boom Section.

• To set all boom section widths, press the EQUAL SECTION WIDTH KEY .