Implement Parameters
Figure 3-17: Implement parameters
Figure 3-18: Section Width
Implement Parameters establishes the following:
►Section Width – sets the spraying width during
application.
►Nozzle Preset Setup – where up to five (5) sets of
nozzle options can be established to set the nozzle
type, size, low/high pressure limit, reference flow and
reference pressure.
►Regulation Parameters – where adjustments to the
valve calibration, nozzle spacing and regulations mode
can be established.
Section Width
Section Width sets the spraying width during application.
Boom Section Width
Section Width establishes the boom sections widths for
each boom section.
NOTE: The number of boom sections available is set on
the Implement Parameters screen in the OEM
section.
• To select the Boom Section Width, use the number
pad or slide bar.
When the section widths are changed, power must be
cycled in order to update the TASC Controller on the VT.
One-Touch Equal Widths
One-Touch Equal Widths sets all boom section widths to
the value set for #1 Boom Section.