Mouse Synchronization
At times, the local mouse movement may lose sync with the remote mouse movement. You can

try getting them back in sync with fast mouse synchronization by moving the mouse pointer

down into the Java Applet toolbar. If that does not help, run Auto sync (as discussed on the

previous page).
1. If Auto sync does not resolve the problem, the Mouse Synchronization function can get them

back into sync. This is similar to the Mouse Synchronization feature of the Windows Client.

2. Click the Mouse Synchronization button. The remote mouse pointer moves to the upper left

area of the screen.

3. Move your local mouse pointer directly over the remote mouse pointer and Click. mouse adj.

The Message Board
Please refer to pg. 34 for a detailed explanation of the Message Board function.

Administrator Reset
The following procedure will reset the default username and password in the event that the

Username and Password information has become corrupted or lost.
To clear the login information (and return all settings to their defaults), do the following:
1. Disconnect the power adapter and all cables.
2. Remove the housing from the SV1107IPEXT.
3. Short jumper J9 on the circuit board.
4. Reconnect the SV1107IPEXT power adapter.
5. When the front panel LEDs flash, disconnect the power adapter from the SV1107IPEXT.
6. Remove the jumper cap from J9.
7. Close the housing and reconnect the SV1107IPEXT power adapter and cables.
8. After starting back up, you can use the default Username and Password to log in.
Please Note: Performing this procedure also returns all settings to their defaults. It will not

remove Users or their passwords.