Carrier Access Access Bank II SNMP User Manual
Page 67

6-6
9/24/01
_____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____
_____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____
3) Span f1[FXS12]: "FXS Channels to KSU"
d1:13 d1:14 d1:15 d1:16 d1:17 d1:18 d1:19 d1:20 d1:21 d1:22 d1:23 d1:24
4) Span f2[---]: "Analog Slot 2 - Not in Service"
_____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____
•
To check the configuration of the V.35 port:
Access Bank II> v35
- V.35 v1 (768000 bps)
v35 v1
circuitid "V.35 @ 768Kbps to Router"
v35 v1
clkinv none
v35 v1
cts high
v35 v1
datainv none
v35 v1
rxclk internal
v35 v1
speed nx64
•
To set the ip configuration, if required (examples given below):
Access Bank II> ip addr 125.164.0.35
Access Bank II> ip nms1 125.164.0.4
Access Bank II> ip
ip
addr 125.164.0.35
ip
mask 255.255.255.0
ip
gateway 127.0.0.1
ip
nms1 125.164.0.4
ip
nms2
ip
nms3
ip
get "public"
ip
set "public"
ip
trap "public"
•
To set SNMP configurations, if required (examples given below):
Access Bank II> snmp name "Voice and Data Access Multiplexor"
Access Bank II> snmp location "Metro Parkway, Wykham"