Carrier Access Access Bank II SNMP User Manual
Page 65
6-4
9/24/01
Access Bank II> date 01/15/98
Access Bank II> date
- System Time
13:27:10 01/15/1998
6. Check the time information:
Access Bank II> time
- System Time is 13:27:08 01/15/1998
•
To correct the time (example is 5:20 PM):
Access Bank II> time 17:20:00
Access Bank II> time
- System Time is 17:20:05 01/15/1998
7. To change and then recheck the system and circuit names (examples are provided here):
Access Bank II> name system "Consolidated National Bank"
Access Bank II> name circuitid d1 "T1 Circuit AD456-7Y"
Access Bank II> name circuitid d2 "T1 Port 2 - Not in Service"
Access Bank II> name circuitid f1 "FXS Channels to KSU"
Access Bank II> name circuitid f2 "Analog Slot 2 - Not in Service"
Access Bank II> name circuitid v1 "V.35 @ 768Kbps to Router"
Access Bank II> name
- Name Configuration
name
system "Consolidated National Bank"
name
circuitid d1 "T1 Circuit AD456-7Y"
name
circuitid d2 "T1 Port #2 - Not in Service"
name
circuitid f1 "FXS Channels to KSU"
name
circuitid f2 "Analog Slot 2 - Not in Service"
name
circuitid v1 "V.35 @ 768Kbps to Router"