17 power, 18 environmental, 17 power -6 – Carrier Access Access Bank II SNMP User Manual
Page 35: 18 environmental -6, 1 physical dimensions -6, 1 physical dimensions
![background image](/manuals/71119/35/background.png)
3-6
9/24/01
•
Bellcore TR-NWT-000499 Generic Transport Requirements
•
FCC Part 15, Class A for Radiated Emissions Control
•
FCC Part 68, CS-03 for T1 CSU Interface, Network Protection, Line Balance, REN
•
National Electrical Code 1996 Safety Requirements
•
NRTL Safety Listed: UL 1459, 2nd Edition concerning Minimum 600 Vrms Lightning
Protection, CSA
•
IEEE 802.3 10baseT interface
•
EIA RS-232-D
•
RFC 1213, 1573, 1406, 1659
3.17 Power
•
Control Panel DC Power Input Terminal: -48 Vdc with 1 Amp circuit breaker from local
battery
•
Standard Power Source: 115 Vac to -48 Vdc Power Converter Cube
•
Optional Power Source: 220 Vac to -48 Vdc Power Converter Cube
•
Input voltage: -42 to -60 Vdc at 1 Amp (constant current power source)
3.18 Environmental
•
Altitude: 0 to 10,000’ (0 to 3,048 m)
•
Humidity: 0 to 95%
•
Temperature Range: 32º to 104º F (0º to 40º C)
•
Thermal Protection: Automatic cut-off at 104ºF (40º C) until lowered below limit
3.18.1 Physical Dimensions
•
Height: 1.75 inches (4.45 cm)
•
Depth: 17.75 inches (45.1 cm)
•
Width: 17 inches (43.2 cm)
•
Weight: 14.5 Lbs (6.6 Kg) fully loaded