30 v35 -28, 5 status commands -28, 1 equipment -28 – Carrier Access Access Bank II SNMP User Manual
Page 173: 5 status commands

14-28
9/24/01
14.4.4.30 v35
Use the v35 command to configure parameters for the V.35 data port to be accessed by the SNMP
manager via RFC-1659.
14.4.5 Status Commands
14.4.5.1equipment
Use the equipment command to display the hardware equipment configuration within the Access
Bank.
Operations
Type
Comments
To set the circuit ID to
“V.35 - 1”
v35 circuitid “V.35 - 1”
Sets the Circuit Id for the V.35 port
To set clock inversion to
receive clock inverted
v35 clkinv rx
Sets the receive clock to be inverted.
To set CTS to follow
RTS signal
v35 cts rts
Sets CTS to follow RTS signal
To set data inversion
v35datainv invert
Sets the V.35 data to be inverted.
To set receive clock
source to be internal
v35 rxclk internal
Sets thte system to use the Internal
Clock.
To set the speed to be
nx56
v35 speed nx56
Sets the data raste to Nx56 KBps
To display Help
v35 ?
Operations
Type
Comments
To display the equipment
list
equipment
Displays a list of the current installed
hardware and Firmware revision
levels.