Carrier Access Access Bank II SNMP User Manual
Page 162

Command Line Interface (CLI)
9/24/01
14-17
interface ..........IP Interface
leds ...............Leds on unit
signal .............FX Signal Type by Channel
snmp ...............SNMP Interface
tcp ................TCP Interface
udp ................UDP Interface
xmodem .............XMODEM Interface
telnet ...............Set Telnet Session Configuration
echo ...............Echo Telnet output on serial line
off ...............Disable echo
on ................Enable
echo
time .................Display/Set Time: time hr:mm:ss
trap .................Send Warm Start Trap to SNMP
n up|down ..........Send Link Up or Link Down for I/F #n
v35 ..................Display/Set V.35
circuitid ..........V.35 Circuit ID
clkinv .............Clock Inversion
none ..............No Clocks Inverted
rx ...............Receive Clock Inverted
rxtx ..............Both Clocks Inverted
tx ................Transmit Clock Inverted
cts ................CTS Signal Control
cd ................CTS Follows CD Signal
high ..............CTS Always High
low ...............CTS Always Low
rts ...............CTS Follows RTS Signal
datainv ............Data Inversion
invert .............Data Inverted
none ..............Data Not Inverted
rxclk
.............Receive Clock Source
internal .........Internal Clock (same as TX)
external .........External Clock
send
..............Send Test Data on Port
clear ............Clear Test Data Statistics
error ............Inject Single Error on Port
off ..............Stop Send for Normal Operations
loopdown .........Send In-Band Remote Loop Down
loopup ...........Send In-Band Remote Loop Up
statistics .......Display Send Statistics
network ..........Send Pattern to Network
[p] [r] ........p - optional pattern
alt
- alternating 1/0
d4up
- D4 loopup: 00001
d4dn
- D4 loopdown: 001
ones
- all ones
p1in8
- 00000001
p511
- O.153
p2047
- O.152