11 fxo/dpt voice card, 12 4-wire e&m/to voice card, 13 network management – Carrier Access Access Bank II SNMP User Manual
Page 33: 11 fxo/dpt voice card -4, 12 4-wire e&m/to voice card -4, 13 network management -4
![background image](/manuals/71119/33/background.png)
3-4
9/24/01
defined signaling options.)
•
DC Loop Range: 1200 ohms (3 miles on 24 AWG + 300 ohms telephone)
•
Loop Feed: Nominal -48 Vdc with 30 mA current limit
•
Separate Transmit/Receive Gain Settings on a Per Channel Basis
•
All-channel simultaneous ringing power: 85 Vrms at 20 Hz
•
Built-in ringback tones
•
Battery Reversal FXS/DPO Voice Card
•
FXS Loop Start with Battery Reversal or Dial Pulse Originating (DPO) functionality per
card
•
Optional Cadenced Ringback Tone (two-seconds on, four seconds off) to the T1 line dur-
ing incoming calls, synchronized to the ringing voltage present on the loop
•
Optional Cadenced Ringing Voltage applied to CPE loop during an incoming call
•
Supports CLASS® services, including Caller ID
3.11 FXO/DPT Voice Card
•
FXO Loop-Start/Ground-Start terminations per channel
•
Dial Pulse Termination (DPT) functionality per card
•
Separate transmit and receive gain settings per channel
•
DID and DNIS carrier services
•
CLASS® services, including distinctive ringing and caller ID
3.12 4-Wire E&M/TO Voice Card
•
Optioned with on-board jumpers to support E&M signaling types I, II, IV, or V, for each
channel
•
Supports Transmission Only (TO) for dedicated modems, radio/paging systems, etc.
•
Separate gain and loss settings from +10 dB to -21 dB for both transmit and receive paths
for each channel
•
Maximum analog transmission level of +9.5 dBm
3.13 Network Management
•
RS-232 Primary Management Port, Cable, Command Line Interface, and MS Windows-
based Remote Monitor Graphical User Interface (GUI) software program included with