Form I-X, P/N 150491 R10, Page 8

All piping must be in accordance with requirements outlined in the National Fuel Gas

Code ANSI/Z223.1a (latest edition) or CAN/CGA-B149.1 and B149.2 (See Paragraph

1.4). Gas supply piping installation should conform with good practice and with local

codes.

Duct furnaces for natural gas are orificed for operation with gas having a heating value

of 1000 (±50) BTU per cubic ft. If the gas at the installation does not meet this specifica-

tion, consult the factory for proper orificing.
Pipe joint compounds (pipe dope) shall be resistant to the action of liquefied

petroleum gas or any other chemical constituents of the gas being supplied.
Install a ground joint union and manual shutoff valve upstream of the unit control sys-

tem, as shown in

FIGURE 8. The 1/8" plugged tapping in the shutoff valve provides

connection for supply line pressure test gauge. The National Fuel Gas Code requires

the installation of a trap with a minimum 3" (76mm) drip leg. Local codes may require a

minimum drip leg longer than 3" (76mm) -- typically 6" (152mm).
Gas connection sizes are listed in

FIGURE 8. After all connections are made, discon-

nect the pilot supply at the control valve and bleed the system of air. Reconnect the

pilot line and leak-test all connections by brushing on a soap solution.

From Gas Supply

(horizontal or vertical)

Manual shutoff

Pipe nipple extending

outside the cabinet.

Drip

Leg

To Gas Valve

To Gas Valve

Ground

Joint

Union

Drip

Leg

Ground Joint Union

Manual shutoff

FIGURE 8 - Supply Piping Connection

Thermostat Wire

Manual Shutoff Valve

with 1/8” NPT plugged

tap must be installed

above the unit casing.

Line Voltage (Supply)

Junction

Box

To Gas Controls

and Burner

Ground

Joint

Union

Top View

Side View

4” (102mm)

2-3/32” (53mm)

5-5/8” (143mm)

6-7/8” (175mm)

7/8” (22mm) dia.

1-7/8” x 1-3/8” (48x35mm)

FIGURE 9 - Gas and Electric Connections

Gas Connection to

Single-Stage Valve

(Not Gas Supply Line Size)

Unit Size

75-250

300-400

Natural Gas

1/2"

3/4"

Propane

1/2"

1/2"

Sizing a Gas Supply

Lines

Capacity of Piping

Cubic Feet per Hour based on 0.3" w.c. Pressure Drop

Specific Gravity for Natural Gas -- 0.6 (Natural Gas -- 1000 BTU/Cubic Ft)

Specific Gravity for Propane Gas -- 1.6 (Propane Gas -- 2550 BTU/Cubic Ft)

Length

Diameter of Pipe

of

1/2"

3/4"

1"

1-1/4"

1-1/2"

2"

Pipe

Natural Propane Natural Propane Natural Propane Natural Propane Natural Propane Natural Propane

20'

92

56

190

116

350

214

730

445

1100

671

2100

1281

30'

73

45

152

93

285

174

590

360

890

543

1650

1007

40'

63

38

130

79

245

149

500

305

760

464

1450

885

50'

56

34

115

70

215

131

440

268

670

409

1270

775

60'

50

31

105

64

195

119

400

244

610

372

1105

674

70'

46

28

96

59

180

110

370

226

560

342

1050

641

80'

43

26

90

55

170

104

350

214

530

323

990

604

90'

40

24

84

51

160

98

320

195

490

299

930

567

100'

38

23

79

48

150

92

305

186

460

281

870

531

125'

34

21

72

44

130

79

275

168

410

250

780

476

150'

31

19

64

39

120

73

250

153

380

232

710

433

175'

28

17

59

36

110

67

225

137

350

214

650

397

200'

26

16

55

34

100

61

210

128

320

195

610

372

Note: When sizing supply lines, consider possibilities of future expansion and increased requirements.

Refer to National Fuel Gas Code for additional information on line sizing.

6.0 Mechanical

(cont'd)

6.1 Gas Piping

and Pressures

(cont'd)

WARNING

All components of a gas supply system must be leak tested prior to placing equipment in service.

NEVER TEST FOR LEAKS WITH AN OPEN FLAME. Failure to comply could result in personal injury,

property damage or death.