Wiring diagrams for match-lit pilot discontinued, In 2003, Appendix (cont'd) – Reznor X Unit Installation Manual User Manual

Page 30

background image

Form I-X, P/N 150491 R10, Page 30

FAN

CONTROL

7

8

9

10

11

12

13

14

15

16

17

18

BLOWER

MOTOR

CUSTOMER'S

CONTACTOR

COIL

CR

12

OPTIONAL DISCONNECT SWITCH

115/1/60

G

GRD

1

3

OPT. FAN CONTROL

OPT. S/W SWITCH

BL

R

BK

BK

Y

Y

LIMIT

CONTROL

W

SINGLE ST

AGE

THERMOS

TAT

SET

ANTICI

PAT

OR

AT

0.4

A

MP

S

R

OPTIONAL

26

25

24

23

22

21

20

19

BK

BR

18

A

CH

B

13

HEATER

BLOCKED VENT

SWITCH

MANUAL RESET

Y

27

OPTIONAL

GAS VALVE

SINGLE STAGE

ENERGY

(SEE NOTE 5)

CUTOFF

TR

TH

Y

Y

BR

BK

Y

20 VA. CONTROL

BK

O

24V

115 VOLT

BR

TRANSFORMER

W

G

GRD

2. THERMOSTAT CALLS FOR HEAT ENERGIZING THE SINGLE STAGE GAS VALVE,

3. FAN CONTROL SENSES HEAT EXCHANGER TEMPERATURE, ENERGIZING THE

OPERATING SEQUENCE

1. FOLLOW LIGHTING INSTRUCTIONS AND ESTABLISH PILOT.

BLOWER MOTOR.

FIRING UNIT AT FULL RATE.

PREVENT VOLTAGE DROP BEYOND FIVE PERCENT OF SUPPLY LINE VOLTAGE.

6. LINE AND BLOWER MOTOR BRANCH CIRCUIT WIRE SHOULD BE SIZED TO

3. THE FOLLOWING CONTROLS ARE SUPPLIED BY REZNOR FOR FIELD INSTALLATION:

2. THE FOLLOWING CONTROLS ARE FACTORY SUPPLIED OPTIONS:

1. THE FOLLOWING CONTROLS ARE FIELD INSTALLED OPTIONS:

FAN CONTROL AND S/W SWITCH

NONE

DISCONNECT SWITCH, THERMOSTAT

NOTES

5. CAUTION: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE

MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING

A TEMPERATURE RATING OF AT LEAST 105 DEGREES C., EXCEPT FOR ENERGY

CUTOFF OR BLOCKED VENT SWITCH WIRE WHICH MUST BE 150 DEGREES C.

8. USE #18 GA. FOR 24 VOLT CONTROL WIRING ON UNIT.

7. USE #14 GA. WIRE FOR LINE AND MOTOR WIRING ON UNIT.

BY OTHERS: NONE

4. DOTTED WIRING AND THE FOLLOWING CONTROLS ARE SUPPLIED AND INSTALLED

WD 113235 REV. #5

WHITE - W

PURPLE - PR

BLUE - BL

GREEN - G

YELLOW - Y

ORANGE - O

RED - R

BROWN - BR

BLACK - BK

WIRING CODE

TOTAL WIRE MINIMUM RECOMMENDED

LENGTH WIRE SIZE

150 FEET #18 GA.

250 FEET #16 GA.

350 FEET #14 GA.

FIELD CONTROL WIRING

FACTORY WIRING

FIELD WIRING

OPTIONAL FACTORY WIRING

FIGURE 30 - For Reference Only, W. D. 113235 for Model X with Standard Match-Lit Pilot and

Standard Single-Stage Gas Valve - APPLIES ONLY TO UNITS MANUFACTURED PRIOR TO 10/03.

X-HX-CX-HCX AG2-CL7 WD 115936

TOTAL WIRE MINIMUM RECOMMENDED

LENGTH WIRE SIZE

150 FEET #18 GA.

250 FEET #16 GA.

350 FEET #14 GA.

FIELD CONTROL WIRING

WHITE - W

PURPLE - PR

BLUE - BL

GREEN - G

YELLOW - Y

ORANGE - O

RED - R

BROWN - BR

BLACK - BK

WIRING CODE

LINE VOLT

OPTIONAL DISCONNECT SWITCH

BL

GRD

G

115/1/60

BK

20 VA. CONTROL

TRANSFORMER

BR

W

OPT. S/W SWITCH

OPT. FAN CONTROL

BL

1

3

R

24V

CR

11

BK

18
CH

A

B

BR

HEATER

FAN

CONTROL

OPTIONAL

12

GAS VALVE

COMBINATION

TWO STAGE

THERMOCOUPLE

R

ENERGY

(SEE NOTE 4)

CUT-OFF

BR

W2

HIGH

C2

BK

W1

C1

LO

W

ST

AG

E

ST

AG

E

BR

RH

SET ANTICI

PAT

OR A

T 0.4 AMP

S

OP

T.

T874F THERMOS

TA

T Q674G SUBBASE

W2

W1

RC

Y

Y

LIMIT

CONTROL

VENT SWITCH

BLOCKED

MANUAL RESET

R

Y

Y

Y

Y

BK

Y

24

25

23

22

21

20

18

19

17

16

15

14

12

13

11

10

7

9

8

6

8 VA. MAXIMUM

BLOWER RELAY COIL

CUSTOMER'S 24 VOLT

R

BL

PREVENT VOLTAGE DROP BEYOND FIVE PERCENT OF SUPPLY LINE VOLTAGE.

6. LINE AND BLOWER MOTOR BRANCH CIRCUIT WIRE SHOULD BE SIZED TO

1. THE FOLLOWING CONTROLS ARE SUPPLIED BY REZNOR FOR FIELD INSTALLATION:

2. THE FOLLOWING CONTROLS ARE SUPPLIED AS OPTIONAL EQUIPMENT.

NONE

DISCONNECT SWITCH, THERMOSTAT, FAN CONTROL AND S/W SWITCH

NOTES

5. CAUTION: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE

MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING

A TEMPERATURE RATING OF AT LEAST 105 DEGREES C., EXCEPT FOR BLOCKED

VENT SWITCH OR SENSOR LEAD WIRE WHICH MUST BE 150 DEGREES C.

8. USE #18 GA. FOR 24 VOLT CONTROL WIRING ON UNIT.

7. USE #14 GA. WIRE FOR LINE AND MOTOR WIRING ON UNIT.

BY OTHERS: NONE

3. DOTTED WIRING AND THE FOLLOWING CONTROLS ARE SUPPLIED AND INSTALLED

4. WARNING: AN ECO CIRCUIT INTERRUPTION IS A MAJOR FAILURE CAUSED BY A

OF THE PRIMARY SAFETY CONTROLS OR MIS-WIRING.

1. SET THERMOSTAT SYSTEM SWITCH AT "OFF" POSITION.

2. FOLLOW LIGHTING INSTRUCTIONS AND ESTABLISH PILOT.

3. SET THERMOSTAT SYSTEM SWITCH AT "AUTO" POSITION.

OPERATING SEQUENCE

7. SET THERMOSTAT SYSTEM SWITCH AT "OFF" POSITION FOR SHUTDOWN.

(A) FAN CONTROL KEEPS THE BLOWER MOTOR ON WHILE UNIT IS HOT.

4. LOW STAGE OF THERMOSTAT CALLS FOR HEAT ENERGIZING THE LOW STAGE GAS VALVE.

5. FAN CONTROL SENSES HEAT EXCHANGER TEMPERATURE ENERGIZING THE BLOWER MOTOR.

6. HIGH STAGE OF THERMOSTAT CALLS FOR HEAT ENERGIZING THE HIGH STAGE GAS VALVE.

MALFUNCTION

FACTORY WIRING

FIELD WIRING

OPT. FACTORY WIRING

FIGURE 31 - For Reference Only, W.D. 115936 for Model X with Standard Match-Lit Pilot and

Optional Two-Stage Gas Valve - APPLIES ONLY TO UNITS MANUFACTURED PRIOR TO 10/03.

Wiring Diagrams for Match-Lit Pilot Discontinued in 2003

APPENDIX (cont'd)