beautypg.com

Conair 100 User Manual

Page 68

background image

6 - 2

l Tr o u b l e s h o o t i n g

B e f o r e B e g i n n i n g

You can avoid most problems by following the recommended installation and
maintenance procedures outlined in this User Guide. If you do have a problem,
this section will help you determine what caused it and how to fix it.

Before you take the side panels off of the dryer be sure to:

Diagnose causes from the control panel.

1

Press once to silence the optional audible alarm and display the

alarm message.

2

Address the alarm message and fix the problem.

3

Press again to clear the alarm. If the alarm reappears the problem

was not fixed.

If the alarm is a passive alarm you will see P in the screen title display.

If the alarm is a shut down alarm you will see A in the screen title

dis

play.

Diagnose causes from the front of the dryer.
You can locate any problem from the front of the dryer.

Set Point

Actual

1 Process Temp.
2 Regen. Temp.
3 Return Air Temp.
4 Auto Start
5 Load Time (MDC)
6 Activate Setback Temp.
7 Setback Temp.(Process)
8 Setback Load Rate
9 PM1 Dewpoint

Shutdown Alarms
A1 Process High Temp.
A2 Process Loop Break
A3 Process Heater High Temp.
A4 Regen. Heater High Temp.
A5 Carousel Index Too Long
A6 Carousel Index Failure
A7 Return Air High Temp.

Passive Alarms
P1 Process Temp. Deviation
P3 Regen. Temp. Deviation
P5 Return Air High Temp.

Auto Start

Desiccant Indexing

Set-Back Temp.

Process Blower

Process Pressure

Process Heater

Regen. Blower

Regen. Pressure

Regen. Heater

Acknowledge
alarm button

Scroll
button

This manual is related to the following products: