Before you call, Equipment guarantee – Conair 100 User Manual
Page 102
![background image](/manuals/70770/102/background.png)
✐
C l e a n i n g t h e A f t e r c o o l e r
If you have the optional aftercooler, you need to clean the aftercooler coils
to keep them working efficiently. Cleaning frequency depends on the type
and amount of material you process.
1
Stop the dryer and lockout the main power.
2
Turn off the water flow to the water supply line. Disconnect supply
and return lines.
3
Remove the plastic aftercooler cover.
NOTE: If an optional flow control was added with the aftercooler, remove the compres-
sion fitting from the aftercooler inlet. Loosen the fitting on the flow control, then swing
the copper water supply tube out and away from the aftercooler inlet.
4
Remove the five screws securing the aftercooler in the aftercooler
housing.
✒
TIP: If the aftercooler (without a flow control) was installed using the recommended 24 in.
(61 cm) of flexible hoses, there is no need to disconnect the hoses from the aftercooler
inlet and outlet.
(continued)
C - 3
l A p p e n d i x