beautypg.com

Installing an aftercooler (optional), G-11 – Conair 100 User Manual

Page 106

background image

E - 1

l A p p e n d i x

I n s t a l l i n g a P r e c o o l e r

( O p t i o n a l )

You can add a precooler to the D Carousel Dryer by ordering the optional precool-
er assembly. Installation is easy.

The optional precooler requires a source of city, tower, or chiller water and a dis-
charge or return line. You can use water at temperatures up to 85°F ( 30°C). But
the water flow should be at least 1 gal/min (3.8 liters/min) for models D15, D25,
D50; or 2 gal/min (7.6 liters/min) for models D75 and D100.

1

Stop the dryer and lockout the main power.

2

Remove the left dryer side panel.

3

Mount the precooler to the back of the dryer using existing holes and the
5/16-8 bolts provided. Note that for D 15, 25, and 50 models, the precooler is
mounted to the dryer with the water fittings and precooler air outlet at the top.
On D 75 and 100 models, the precooler is mounted with the water fittings and
precooler air outlet at the bottom.

4

Connect the process air outlet hose to the precooler air inlet tube and tight-
en the clamp provided.

5

Connect the hopper air inlet air hose to the precooler air outlet tube and
tighten the clamp provided.

Note: If an optional flow control was ordered with the precooler,

see Appendix E

"Optional Flow Control" for information on connecting the water supply.

Note: If the optional Conair flow control valve was not ordered with the dryer, it is
strongly recommended that a customer-supplied manual flow control valve be installed
on the water inlet line.

6

Connect the water supply line to the precooler inlet. If a manual shut off
valve is used, it should be mounted on the inlet line.

(continued)

TIP: Make the water supply and dis-

charge / return connections with

flexible hoses at least 24 in. (61 cm)

long. This allows you to easily

remove the precooler assembly for

cleaning.

TIP: If an optional flow control is also

being installed with the precooler,

the manual shut off valve should be

installed on the inlet line for the flow

control.

This manual is related to the following products: