G - 2
l A p p e n d i x
NOTE: Throughput rates will
vary by MDC model and type of
material. See the Specification
pages for recommended
throughputs.
Ty p i c a l A p p l i c a t i o n s
The MDC was designed for drying and conveying beside the press. But it can also
be used to pre-dry material in one location, and then transport the dried material to
another location for conveying into the processing machine.
The MDC can be used successfully in applications that require:
•
A contamination-free drying environment.
•
Drying temperatures of 100° to 375°F (66° to 191°C).
•
Throughput rates of 15 to 100 lbs (6.8 to 37.3 kg) per hour (some materials can
be run at a higher rate).
•
Dew points of -40°F (-40°C).
•
Conveying material at distances up to, but not more than, 8 feet (2.4 m)
vertically and 6 feet (1.8 m) horizontally.
An aftercooler is required if:
•
You are drying at temperatures over 250°F (121°C).
•
Throughput rates are less than 50% of the dryer’s rated capacity.
•
You are pre-drying material at temperatures over 150°F (66°C).
✐
Central
When configured as
a central dryer, the
MDC option is not
available.