S c r e e n
Screens 15-27 require access
code 754.
SCREEN 15 (Set up Screen)
SCREEN 16 (Set up Screen)
SCREEN 17 (Set up Screen)
SCREEN 18 (Set up Screen)
SCREEN 19 (Set up Screen)
F u n c t i o n
C o n t r o l F u n c t i o n D e s c r i p t i o n s
( c o n t i n u e d )
This is the process deviation temperature
screen. The range is 5 - 20
°
F (-15.0 -
-6.7
°C)
. This is the deviation temperature
band around the set point. If the dryer
goes outside this band, the dryer will dis-
play a passive alarm (P1).
This is the process high temperature
screen. This is the high temperature limit.
If the process temperature reaches this set-
point, the dryer will shutdown on alarm
A1.
This is the process heater autotune screen.
The autotune function can be turned on by
pressing the + key. Once the + key is
pressed, the screen will show On and then
start the autotune process. This may take a
minute or so to complete. When finished,
the display will read "don". The new PID
values are automatically saved.
This is a regeneration temperature screen.
This is the regeneration heater autotune
screen. The autotune function can be
turned on by pressing the + key. Once the
+ key is pressed, the screen will show On
and then start the autotune process. This
may take a minute or so to complete.
When finished the display will read "don".
The new PID values are automatically
saved.