beautypg.com

Maxim Integrated 6612_OMU_S2+2_URT_V1_14 User Manual

Page 50

background image

6612_OMU_S2+2_URT_V1_14 Firmware Description Document

UG_6612_017

50

Rev. 1.0

CE

Parameter

Location(

hex)

LSB

Default

Comment

Example

QUANTA

12

VMAX A *

IMAX A *
1.8541E-

10 (W att)

0

Compensation

added to the Watt

calculation for

Outlet 1. Used for

compensation at

low current levels.

Keep below

10000d.

QUANTB

13

VMAX A *

IMAX B *
1.8541E-

10 (W att)

0

Compensation

added to the Watt

calculation for

Outlet 2. Used for

compensation at

low current levels.

Keep below

10000d.

QUANT

VAR A

14

VMAX A *

IMAX A *
1.8541E-

10 (W att)

0

Compensation

added to the VAR

calculation for

Outlet 1. Used for

compensation at

low current levels.

Keep below

10000d.

QUANT

VAR B

15

VMAX A *

IMAX B *
1.8541E-

10 (W att)

0

Compensation

added to the VAR

calculation for

Outlet 2. Used for

compensation at

low current levels.

Keep below

10000d.

QUANT IA

16

(IMAX A)

2

*

4.6351E-11

(A

2

)

0

IA input

compensation

added for input

noise and

truncation in the

squaring

calculation for I

2

.

Used for

compensation at

low current levels.

Keep below

10000d.

QUANT IB

17

(IMAX B)

2

*

4.6351E-11

(A

2

)

0

IA input

compensation

added for input

noise and

truncation in the

squaring

calculation for I

2

.

Used for

compensation at

low current levels.

Keep below

10000d.

Reserved

18

Reserved

Reserved