Maxim Integrated 6612_OMU_S2+2_URT_V1_14 User Manual
Page 50
![background image](/manuals/698442/50/background.png)
6612_OMU_S2+2_URT_V1_14 Firmware Description Document
UG_6612_017
50
Rev. 1.0
CE
Parameter
Location(
hex)
LSB
Default
Comment
Example
QUANTA
12
VMAX A *
IMAX A *
1.8541E-
10 (W att)
0
Compensation
added to the Watt
calculation for
Outlet 1. Used for
compensation at
low current levels.
Keep below
10000d.
QUANTB
13
VMAX A *
IMAX B *
1.8541E-
10 (W att)
0
Compensation
added to the Watt
calculation for
Outlet 2. Used for
compensation at
low current levels.
Keep below
10000d.
QUANT
VAR A
14
VMAX A *
IMAX A *
1.8541E-
10 (W att)
0
Compensation
added to the VAR
calculation for
Outlet 1. Used for
compensation at
low current levels.
Keep below
10000d.
QUANT
VAR B
15
VMAX A *
IMAX B *
1.8541E-
10 (W att)
0
Compensation
added to the VAR
calculation for
Outlet 2. Used for
compensation at
low current levels.
Keep below
10000d.
QUANT IA
16
(IMAX A)
2
*
4.6351E-11
(A
2
)
0
IA input
compensation
added for input
noise and
truncation in the
squaring
calculation for I
2
.
Used for
compensation at
low current levels.
Keep below
10000d.
QUANT IB
17
(IMAX B)
2
*
4.6351E-11
(A
2
)
0
IA input
compensation
added for input
noise and
truncation in the
squaring
calculation for I
2
.
Used for
compensation at
low current levels.
Keep below
10000d.
Reserved
18
–
–
Reserved
Reserved