4 auxiliary commands, 1 repeat command, Auxiliary commands – Maxim Integrated 6612_OMU_S2+2_URT_V1_14 User Manual
Page 11: Repeat command

UG_6612_ 017
6612_OMU_S2+2_URT_V1_14 Firmware Description Document
Rev. 1.0
11
4.4 Auxiliary Commands
4.4.1 Repeat Command
The repeat command can be useful for monitoring measurements and is efficient in demands from the
host.
If the host requests line frequency, alarm status, Irms nb overcurrent event count, Vrms SAG event count,
Vrms overvoltage event count, voltage, power, and accumulated energy measurements for Outlet 1 with
the following command string:
>)01????????
If the host then desires this same request without issuing another command, the repeat command can be
used:
>, (no carriage return needed for the repeat command)
The host only needs to send one character rather than an entire string.
Auxiliary
Description:
Various
Commands:
,
Typing a comma (“,”) repeats the command
issued from the previous command line. This is
very helpful when examining the value at a
certain address over time, such as the CE
DRAM address for the temperature.
/
The slash (“/”) is useful to separate comments
from commands when sending macro text files
via the serial interface. All characters in a line
after the slash are ignored.