Table 3: outlet 1 mpu outputs for wideband method – Maxim Integrated 6612_OMU_S2+2_URT_V1_14 User Manual

Page 24

background image

6612_OMU_S2+2_URT_V1_14 Firmware Description Document

UG_6612_017

24

Rev. 1.0

Output

Location

(hex)

LSB

Comment

Example

Phase

Angle_nb A

Max

1D

Outlet 1 maximum narrowband

phase angle measured.

If the maximum narrowband phase

angle measured on Outlet 1 is 70

degrees

)1D?

Returns:

+70.000

Reserved

1E

Reserved

Reserved

Reserved

1F

Reserved

Reserved


Table 3 lists the wideband measurement outputs for Outlet 1.

Table 3: Outlet 1 MPU Outputs for Wideband Method

Output

Location

(hex)

LSB

Comment

Example

Delta

Temperature

20

0.1 °C

Temperature difference from 22° C.

Note: Duplicate of address 0x00

(see

Table 2

)

If external temperature is 32 °C

)20?

Returns:

+10.0

Line

Frequency

21

0.01 Hz

Line Frequency

Note: Duplicate of address 0x01

(see

Table 2

)

If the line frequency is 60 Hz:

)21?

Returns:

+60.00

Alarm Status

22

Bit 0 – Minimum Temperature

Alarm.

Definition for Status Register

Bit 1 – Maximum Temperature Alarm.

Bit 2 – Minimum Frequency Alarm.

Bit 3 – Maximum Frequency Alarm.

Bit 4 - SAG Voltage Alarm.

Bit 5 – MINVA

under minimum

voltage on VA input.

Bit 6 – MAXVA

over maximum

voltage on VA input.

Bit 7 – MAXIA_NB

maximum

narrowband current exceeded on

Outlet 1.

Bit 8 – MAXIA_WB

maximum

wideband current exceeded on

Outlet 1.

Bit 9 – PFA_NB negative –

Narrowband Power Factor Negative

Threshold Alarm for Outlet 1. Only

available is )F2 bit 2 is 1.

Bit 10 – PFA_NB positive

Narrowband Power Factor Positive

Threshold Alarm for Outlet 1.

Bit 11 – PFA_WB negative -

Wideband Power Factor Negative

Threshold Alarm for Outlet 1. Only

available is )F2 bit 2 is 1.

Bit 12 – PFA_WB positive

Wideband Power Factor Positive

Threshold Alarm for Outlet 1.

Bit 13 – MAXIB_NB

maximum

narrowband current exceeded on

Outlet 2.

Alarms become “1” when

thresholds exceeded.

Note: Additional Status Alert is

Located at addr 0xBD (see

Table 8

)

Note: When AC voltage input is less

than or equal to 10 V

RMS

,

Only MINVA alarm is active.

All measurements are forced
to 0 except power factor,
which is forced to 1.

Note: The frequency measurement

is forced to 0 as long as the SAG

voltage alarm is active.