Maxim Integrated 6612_OMU_S2+2_URT_V1_14 User Manual
Page 27
![background image](/manuals/698442/27/background.png)
UG_6612_ 017
6612_OMU_S2+2_URT_V1_14 Firmware Description Document
Rev. 1.0
27
Output
Location
(hex)
LSB
Comment
Example
Watts A Max
33
mW
Maximum Outlet 1 active power
measured (per second)
Note: Duplicate of address 0x13
(see
).
If the maximum power measured
on Outlet 1 is 200 Watts
)33?
Returns:
+200.000
Irms_wb A
Min
34
mArms
Outlet 1 minimum wideband rms
current measured.
If the smallest wideband current
measured on Outlet 1 is 1 Amp
)34?
Returns:
+1.000
Irms_wb A
Max
35
mArms
Outlet 1 maximum wideband rms
current measured.
If the largest wideband current
measured on Outlet 1 is 30 Amps
)35?
Returns:
+30.000
VARs_wb A
Min
36
mW
Outlet 1 minimum wideband
reactive power measured (per
second).
If the largest VARs measured on
Outlet 1 is 80 VARs
)36?
Returns:
+80.000
VARs_wb A
Max
37
mW
Outlet 1 maximum wideband
reactive power measured (per
second).
If the largest VARs measured on
Outlet 1 is 300 VARs
)37?
Returns:
+300.000
VAs_wb A
Min
38
mW
Outlet 1 minimum wideband
apparent power measured (per
second).
If the smallest VAs measured on
Outlet 1 is 80 VARs
)38?
Returns:
+80.000
VAs_wb A
Max
39
mW
Outlet 1 maximum wideband
apparent power measured (per
second).
If the largest VAs measured on
Outlet 1 is 300 VARs
)39?
Returns:
+300.000
Power
Factor_wb A
Min
3A
–
Outlet 1 minimum wideband power
factor measured. Minimum is
defined as the most negative or
least positive number.
If minimum wideband power factor
measured on Outlet 1 is –0.6
)3A?
-0.600
Power
Factor_wb A
Max
3B
–
Outlet 1 maximum wideband power
factor measured. Maximum is
defined as the most positive or
least negative number.
If maximum wideband power factor
measured on Outlet 1 is 0.9
)3B?
+0.900
Phase
Angle_wb A
Min
3C
–
Outlet 1 minimum wideband phase
angle measured.
If the minimum wideband phase
angle measured on Outlet 1 is 10
degrees
)3C?
Returns:
+10.000
Phase
Angle_wb A
Max
3D
–
Outlet 1 maximum wideband phase
angle measured.
If the maximum wideband phase
angle measured on Outlet 1 is 70
degrees
)3D?
Returns:
+70.000
Reserved
3E-3F
–
Reserved
Reserved