5 MPU Measurement Outputs
This section describes the measurement outputs that can be obtained. Energy outputs are accumulated
numbers. The host accessing the measurement information from the 78M6612 more frequently will not
result in any update in the information.
Table 2 lists the Narrowband outputs for Outlet 1.
Table 2: Outlet 1 MPU Outputs for Narrowband Method
Output
Location
(hex)
LSB
Comment
Example
Delta
Temperature
00
0.1 °C
Temperature difference from 22 °C.
If external temperature is 32 °C
)00?
Returns:
+10.0
Line
Frequency
01
0.01 Hz
Line Frequency.
If the line frequency is 60 Hz:
)01?
Returns:
+60.00
Alarm Status
02
Bit 0 – Minimum Temperature Alarm.
Definition for Status Register
Bit 1 – Maximum Temperature
Alarm.
Bit 2 – Minimum Frequency Alarm.
Bit 3 – Maximum Frequency Alarm.
Bit 4 - SAG Voltage Alarm.
Bit 5 – MINVA
–
under minimum
voltage on VA input.
Bit 6 – MAXVA
–
over maximum
voltage on VA input.
Bit 7 – MAXIA_NB
–
maximum
narrowband current exceeded on
Outlet 1.
Bit 8 – MAXIA_WB
–
maximum
wideband current exceeded on
Outlet 1.
Bit 9 – PFA_NB negative –
Narrowband Power Factor Negative
Threshold Alarm for Outlet 1. Only
available is )F2 bit 2 is 1.
Bit 10 – PFA_NB positive
–
Narrowband Power Factor Positive
Threshold Alarm for Outlet 1.
Bit 11 – PFA_WB negative -
Wideband Power Factor Negative
Threshold Alarm for Outlet 1. Only
available is )F2 bit 2 is 1.
Bit 12 – PFA_WB positive
–
Wideband Power Factor Positive
Threshold Alarm for Outlet 1.
Bit 13 – MAXIB_NB
–
maximum
narrowband current exceeded on
Outlet 2.
Bit 14 – MAXIB_WB
–
maximum
wideband current exceeded on
Outlet 2.
Alarms become “1” when
thresholds exceeded.
Note: Additional Status Alert is
Located at addr 0xBD
(see
Note: When AC voltage input is
less than or equal to 10 V
RMS
,
•
Only MINVA alarm is active.
•
All measurements are
forced to 0 except power
factor, which is forced to 1.
Note: The frequency
measurement is forced to 0 as
long as the SAG voltage alarm
is active.