Clt command – Maxim Integrated 6612_OMU_S2+2_URT_V1_14 User Manual
Page 15
UG_6612_ 017
6612_OMU_S2+2_URT_V1_14 Firmware Description Document
Rev. 1.0
15
4.5.2.4 CLT Command
The CLT command is used for the temperature calibration. With this command, the contents of CE
register 71 are read and entered into MPU register C0 and the contents are saved to flash. The CLT
command example is given below:
>CLT
The response is:
TCal OK
>
A summary of the atomic calibration commands are given in the table below:
CLxx
Atomic Calibration
Commands
Description:
Allows the user to Calibrate individual sections of the IC.
Usage:
CLV
Calibrates voltage only.
CLI1
Calibrate current on Outlet 1 only.
CLI2
Calibrate current on Outlet 2 only.
CLI3
Calibrate for current on both Outlet 1 and Outlet 2
only.
CLW1
Calibrate for power on Outlet 1 only.
CLW2
Calibrate for power on Outlet 2 only.
CLW3
Calibrate for power on both Outlet 1 and Outlet 2.
CLP
Calibrate for phase on Outlet 1 only. Generally only
used when using current transformers.
CLP2
Calibrate for phase on Outlet 2 only. Generally only
used when using current transformers.
CLP3
Calibrate for phase on both Outlet 1 and Outlet 2.
Generally only used when using current transformers.
CLT
Calibrate temperature only.
The commands that follow are mainly for advanced users and are included for reference only.