beautypg.com

Maxim Integrated 6612_OMU_S2+2_URT_V1_14 User Manual

Page 49

background image

UG_6612_ 017

6612_OMU_S2+2_URT_V1_14 Firmware Description Document

Rev. 1.0

49

CE

Parameter

Location(

hex)

LSB

Default

Comment

Example

CESTATE

0E

5005h

SAG CNT

Bits 15:8 –

determines the

consecutive voltage

samples below

SAG_Threshold

before a sag alarm
is declared. 255 is

the maximum

value.

Pulse Selection

(PULSEL)

Bit 4

0 – chooses Outlet

1 (IA input) for

pulse generation

1 – chooses Outlet

2 (IB input) for

pulse generation.

Reserved

Bit 3

Voltage Sensor

Configuration

Bit 2

0 – Isolated mode

uses VA-VB for

Voltage

1 – Non-isolated

mode uses VA for

voltage; V3P3 must

be tied to NTRL;

VB can be tied to

EGND for reversal

detection

Pulse gain factor

Bits 1 and 0

00 – 6x

01 – (6/64)x

10 – 96x

11 – 1.5x

]0E=5005

Selects at least 80 (50h) consecutive

voltage samples below SAG_Threshold

before SAG alarm.

Select Outlet 1 as pulse source.

Selects VA (non-isolated mode) for

Voltage of both Outlets 1 and 2

Selects Pulse Gain Factor equal to 6/64

WRATE

0F

Kh =

VMAX A *

IMAX A /

(W RATE *

X)

1.6826E+0

1 WattSec

+4860

Controls the

number of pulses

that are generated

per measured Wh

and VARh

measurements.

]0F=+4860

Kh = 0.32 * Wh / pulse with X = 6/64,

VMAX =600 V

and

IMAX = 52 A

Reserved

10

Reserved

SAG

Threshold

11

VMAX A

*4.2551E-

07 (Vpk)

+313350

The voltage

threshold for SAG

warnings. The

default value is 80

Vpk if VMAX = 600

V.

]11=+313350

80 Vpk SAG Threshold.