6612_OMU_S2+2_URT_V1_14 Firmware Description Document

UG_6612_017

32

Rev. 1.0

Table 5 lists the wideband measurement outputs for Outlet 2.

Table 5: Outlet 2 MPU Outputs for Wideband Method

Output

Location

(hex)

LSB

Comment

Example

Delta

Temperature

60

0.1 °C

Temperature difference from 22° C.

Note: Duplicate of address 0x00

(see

Table 2

).

If external temperature is 32 °C

)60?

Returns:

+10.0

Line

Frequency

61

0.01 Hz

Line Frequency

Note: Duplicate of address 0x01

(see

Table 2

).

If the line frequency is 60 Hz:

)61?

Returns:

+60.00

Alarm Status

62

Bit 0 – Minimum Temperature

Alarm.

Definition for Status Register

Bit 1 – Maximum Temperature

Alarm.

Bit 2 – Minimum Frequency Alarm.

Bit 3 – Maximum Frequency Alarm.

Bit 4 - SAG Voltage Alarm.

Bit 5 – MINVA

under minimum

voltage on VA input.

Bit 6 – MAXVA

over maximum

voltage on VA input.

Bit 7 – MAXIA_NB

maximum

narrowband current exceeded on

Outlet 1.

Bit 8 – MAXIA_WB

maximum

wideband current exceeded on

Outlet 1.

Bit 9 – PFA_NB negative –

Narrowband Power Factor Negative

Threshold Alarm for Outlet 1. Only

available is )F2 bit 2 is 1.

Bit 10 – PFA_NB positive

Narrowband Power Factor Positive

Threshold Alarm for Outlet 1.

Bit 11 – PFA_WB negative -

Wideband Power Factor Negative

Threshold Alarm for Outlet 1. Only

available is )F2 bit 2 is 1.

Bit 12 – PFA_WB positive

Wideband Power Factor Positive

Threshold Alarm for Outlet 1.

Bit 13 – MAXIB_NB

maximum

narrowband current exceeded on

Outlet 2.

Bit 14 – MAXIB_WB

maximum

wideband current exceeded on

Outlet 2.

Bit 15 – PFB_NB negative –

Narrowband Power Factor Negative

Threshold Alarm for Outlet 2. Only

available is )F2 bit 2 is 1.

Bit 16 – PFB_NB positive

Narrowband Power Factor Positive

Threshold Alarm for Outlet 2.

Alarms become “1” when

thresholds exceeded.

Note: Additional Status Alert is

Located at addr 0xBD

(see

Table 8

).

Note: When AC voltage input is

less than or equal to 10 V

RMS

,

Only MINVA alarm is
active.

All measurements are
forced to 0 except power
factor, which is forced to 1.

Note: The frequency

measurement is forced to 0 as

long as the SAG voltage alarm is

active.