beautypg.com

Compaq AP500 User Manual

Page 111

background image

4-35

Compaq Professional Workstation AP500 Maintenance and Service Guide

Table 4-28

SCSI Test Error Codes

Error Code

Description

Recommended Action

XXXX-02

Drive not installed.

Check cable connections.

XXXX-03

Media not in drive.

Check for and install DATA CD or write-enabled

tape in drive.

XXXX-05

Seek failure

Replace the indicated device.

XXXX-06

Drive timed out.

Replace the indicated device.

XXXX-07

Drive busy.

Replace the indicated device.

XXXX-08

Drive already reserved.

Replace the indicated device.

XXXX-09

Unknown

XXXX-10

Unknown

XXXX-11

Media soft error

Replace the indicated device.

XXXX-12

Drive not ready.

Replace the indicated device.

XXXX-13

Media error

Replace the indicated device.

XXXX-14

Drive hardware error

Replace the indicated device.

XXXX-15

Illegal drive command

Replace the indicated device.

XXXX-16

Media was changed.

Replace the indicated device.

XXXX-17

Tape write-protected.

1.Disable write-protect on tape cartridge.

2.Replace tape drive.

XXXX-18

No data detected.

Replace the indicated device.

XXXX-21

Drive command aborted.

Replace the indicated device.

65XX-24

Media hard error

1. Back up data and perform Surface Analysis to

reallocate defect.

2. Replace drive.

66XX-24

Media hard error

1. Replace current DATA CD with different DATA

CD and attempt to read.

2. Replace drive.

67XX-24

Media hard error

1. Ensure correct media type for this tape drive.

2. Replace current tape with new tape.

3. Replace tape drive.

XXXX-25

Unknown

Continued