Compaq AP500 User Manual
Page 111
4-35
Compaq Professional Workstation AP500 Maintenance and Service Guide
Table 4-28
SCSI Test Error Codes
Error Code
Description
Recommended Action
XXXX-02
Drive not installed.
Check cable connections.
XXXX-03
Media not in drive.
Check for and install DATA CD or write-enabled
tape in drive.
XXXX-05
Seek failure
Replace the indicated device.
XXXX-06
Drive timed out.
Replace the indicated device.
XXXX-07
Drive busy.
Replace the indicated device.
XXXX-08
Drive already reserved.
Replace the indicated device.
XXXX-09
Unknown
XXXX-10
Unknown
XXXX-11
Media soft error
Replace the indicated device.
XXXX-12
Drive not ready.
Replace the indicated device.
XXXX-13
Media error
Replace the indicated device.
XXXX-14
Drive hardware error
Replace the indicated device.
XXXX-15
Illegal drive command
Replace the indicated device.
XXXX-16
Media was changed.
Replace the indicated device.
XXXX-17
Tape write-protected.
1.Disable write-protect on tape cartridge.
2.Replace tape drive.
XXXX-18
No data detected.
Replace the indicated device.
XXXX-21
Drive command aborted.
Replace the indicated device.
65XX-24
Media hard error
1. Back up data and perform Surface Analysis to
reallocate defect.
2. Replace drive.
66XX-24
Media hard error
1. Replace current DATA CD with different DATA
CD and attempt to read.
2. Replace drive.
67XX-24
Media hard error
1. Ensure correct media type for this tape drive.
2. Replace current tape with new tape.
3. Replace tape drive.
XXXX-25
Unknown
Continued