Log recording cycle
0.1~60s(

sec

)

0.1~10s(

sec

)0.1s step

10s~60s(sec)1s step
Initial value: 1.0

sec

Adjust button
- Adjust with the (+) and (-) but-

tons.

- Return to the initial value “0” by

pressing the (+) and (-) buttons
simultaneously for about 1 sec-
ond.

Log recording time
20s (seconds) 3h 20m (3 hours

20 minutes)

The maximum recordable time

set by CYCL is displayed auto-
matically.

Status display
RDY :Throttle trigger operation wait
STA :Logger running
STP : Logger stopped

Alarm ON/OFF
ON, OFF
- Select with the (+) or (-) but-

tons.

113

Fu
n

c

tio

n

Telemetry "TELEMETRY"

1

(Log start operation)

-Start by switch (SW1)

When the switch (SW1) set by SW/dial func-

tion (p.65) is pressed, data logging starts.

-Starting by throttle trigger

Display the log setting (LOG MODE) screen

and select the "STATE" setting item by (JOG)

button up or down operation, and press the

(JOG) button for approximately 1 second.

Log function start/stop operation

2

(Recording cycle setting)

Select the "CYCL" setting item by (JOG) but-

ton up or down operation, and set the data ac-

quisition interval from a minimum 0.1 second

to a maximum 60 seconds with the (+) button

or (-) button.

The maximum recordable time set by CYCL is

displayed at END TIME shown below.

3

(Count alarm ON/OFF)

Select the "ALRM" setting item by (JOG)

button up or down operation. To sound an

electronic beep at each log count, set "ALRM"

to ON with the (+) button or (-) button.

"OFF" : Alarm OFF
"ON"

: Alarm ON at each log count

When ending, move the cursor to [RT] by the (JOG) button,

and return to the HOME screen by pressing the (JOG) but-

ton twice.

An electronic beeping sound is generated and the "STATE" display switches from "RST"

to blinking "RDY", and the logger enters the trigger operation wait state. When the trig-

ger is operated in the forward direction, data logging begins. (STATE display "STA")

When the end time arrives, an electronic beep sounds and data logging stops. To return

to the HOME screen during data logging, move the cursor to [RT] by (JOG) button up or

down operation, and press the (JOG) button or (+) button.

2

(Log forced end)

To abort logging, press the switch (SW1), the same as starting, or display the log setting

(LOG MODE) screen and select the "STATE" setting item by (JOG) button up or down

operation and press the (JOG) button for approximately 1 second. An electronic beeping

sound is generated and logging is stopped.