Flintec FAD-40 User Manual
Page 8
FAD-40 Technical Manual, Rev. 1.06 December 2012
Page 8 of 52
Communication and Setup:
Serial interface
RS232C with 9600 baud (8,N,1);
for FAD-40 and FAD-40MB: RS485 with up to 57600 baud (8N1, 7E1, 7O1)
Other interfaces
Depends on instrument type
Response time
< 4 ms (delay after each read or write command)
Setup and calibration
By PC software via RS232C respective RS485, backup data stored on PC
Digital Inputs + Outputs
2x configurable I/O
Selectively configured as input (10...26 V DC) or
open collector output (24 V DC, max. 100 mA)
1x additional output
Open collector output (24 V DC, max. 100 mA)
Input functions
Zero, tare, clear tare or control input to communication interface
Output functions
Setpoint output with / without hysteresis, tolerance band output or control
output from communication interface
Power supply:
DC power supply
10 to 28 VDC, < 200 mA, not galvanically isolated
Environment and Enclosure:
Operation temperature:
Between -10 °C and +40 °C at maximum 85% RH max, non-condensing
Enclosure and protection
Polyamide, for DIN-rail mounting, IP20
Instrument with RS485 interface: Type FAD-40
Communication:
Serial interface RS485
1200 to 57600 baud (8N1, 7E1, 7O1), bus capability up to 31 units
Communication mode
Requested
Dimensions & weight
99 x 22.5 x 114.5 mm (L x W x H), weighs appr. 110 g
Instrument with Modbus RTU interface: Type FAD-40MB
Communication:
Serial interface RS485
1200 to 57600 baud (8N1, 7E1, 7O1), bus capability up to 31 units
Communication mode
Requested or Modbus RTU
Address range
1...31
Dimensions & weight
99 x 22.5 x 114.5 mm (L x W x H), weighs appr. 110 g
Instrument with Profibus DP interface: Type FAD-40PB
Communication:
Profibus DP-V0 + DP-V1 9,6 kbit/s to 12 Mbit/s (automatic), galvanically isolated interface
Address range
1...126
Dimensions & weight
99 x 45 x 114.5 mm (L x W x H), weighs appr. 150 g
Instrument with ProfiNet interface: Type FAD-40PN
Communication:
ProfiNet
100 Mbit/s (full duplex), galvanically isolated interface
IP settings
DHCP or manual setup by PC software
Dimensions & weight
99 x 45 x 114.5 mm (L x W x H), weighs appr. 150 g
Instrument with Ethernet TCP/IP interface: Type FAD-40EN
Communication:
Ethernet TCP/IP
10 Mbit/s (full duplex), galvanically isolated interface
IP settings
Manual setup by PC software
Dimensions & weight
99 x 45 x 114.5 mm (L x W x H), weighs appr. 150 g
Other
Web client interface