Fad-40px output to plc input 3, Dword – Flintec FAD-40 User Manual

Page 29

background image

FAD-40 Technical Manual, Rev. 1.06 December 2012

Page 29 of 52

FAD-40Px Output to PLC Input 3

rd

Dword

Bit no.

3

rd

Dword Description

D31…D21 Not in use
D20

Input for I/O2

D19

Input for I/O3

D18

Output for I/O3

D17

Output for I/O2

D16

Output for I/O1

D15…D12

Error codes of
converter

0000

No error found

0001

ADC out

0010

ADC over

0011

ADC under

0100

System error

0101

In setup mode

0110

Low/High voltage error

0111

Instrument not found

D11…D10 Not in use

D9

Operation mode

0

Weight & Force Mode

1

Count Mode

D8

Zero range

0

Weight is out of zero range

1

Weight is in of zero range

D7

Indication

0

Gross

1

Net

D6

MD

Motion detection

0

Stable

1

Unstable

D5
D4
D3
D2
D1

Read command
response

00000

Indicated weight

00001

Gross weight

00010

Tare weight

00011

Indicated weight (floating point type)

00100

Gross weight (floating point type)

00101

Tare weight (floating point type)

10000

Calibration Status (Refer to table 8.2)

D0

CMD flag

A change of Flag indicates: The command is applied successfully