beautypg.com

Plc output to fad-40px input, Plc output to fad-40px input 2, Dword – Flintec FAD-40 User Manual

Page 30: I/o configuration

background image

FAD-40 Technical Manual, Rev. 1.06 December 2012

Page 30 of 52

PLC Output to FAD-40Px Input

Dword

D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
D15 D14 D13 D12 D11

D10

D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

1

st

Dword

Reserved

2

nd

Dword

W31

MSB

W30 W29 W28 W27 W26 W25 W24 W23 W22 W21 W20 W19 W18 W17 W16

W15 W14 W13 W12 W11 W10 W9

W8

W7

W6

W5

W4

W3

W2

W1

W0

LSB

3

rd

Dword

Not in use

I/O3

out

I/O2

out

I/O1

out

Not in use

Command List

Data Selection

New

CMD

PLC Output to FAD-40Px Input 2

nd

Dword


The 2

nd

Dword contains the setting / parameter valu

e (Refer to “Adjust span calibration” and “I/O configuration”

in “Command List”, see PLC Output to FAD-40Px Input 3rd Dword).

I/O Configuration

Bit no.

2

nd

Dword description

D0…D6

I/O1 output function

0000000

Disable

0000001

Standard setpoint

0000010

Setpoint without hyster.

0000011

Window

0000100

Host output

D7

I/O1 polarity

0

Active Low

1

Active High

D8…D14

I/O2 output function

0000000

Disable

0000001

Standard setpoint

0000010

Setpoint without hyster.

0000011

Window

0000100

Host output

I/O2 input functions

0000101

Zeroing

0000110

Taring

0000111

Clearing tare

0001000

Host input

D15

I/O2 polarity

0

Active Low

1

Active High

D16…D22

I/O3 output function

0000000

Disable

0000001

Standard setpoint

0000010

Setpoint without hyster.

0000011

Window

0000100

Host output

I/O3 input function

0000101

Zeroing

0000110

Taring

0000111

Clearing tare

0001000

Host input

D23

I/O3 polarity

0

Active Low

1

Active High