13-7 MANUAL DRAWER RELEASING
The drawer opens automatically when a registration is
performed. In the event of a power failure or other trouble,
the drawer can be opened manually in the following
manner;
1.
Insert the Drawer Release Key into the drawer release
lock and turn the key clockwise. The drawer will then
open. (Fig. 1)
2. The Drawer Release Key can be taken out by returning
it to the original position.
3.
When the drawer is closed, it is automatically locked
and will not open without the Drawer Release Key or a
normal registering operation.
13-8 REMOVING THE DRAWER
1.
Pull the drawer out, and when it stops at the stopper,
lift the drawer up and pull it further out {Fig. 2). When
it stops again at the roller fixed in the drawer housing,
lift it and pull it out (Fig. 3).
2.
To return the drawer, follow the reverse procedure for
removing.
13-9 CDC (Cash Drawer Cover) LOCK
Locking (Fig, 4)
1.
Push the Cash Drawer Cover to the back of the
drawer.
2.
Press the cover lightly, insert the key into the key-hole
on the cover, and turn it to lock.
Unlocking
1. Unlock the cover using the key, and lift the front end.