601-11072
All Memory Clear
If the register becomes completely inoperative due to battery discharge or malfunction of the
program memory, the All Memory Clear operation must be carried out. When an All Memory
Clear is operated, all the memory contents that have been stored in the RAM will be cleared (i.e.,
the programmed data and the sales data). Along with the clearing process, the designated zero-
amount format is set and “Initial Data” and “Initial Status” for respective programming items are
automatically set.
Warning
: This clear operation deletes all programmed data and sales data stored in the
register*s memory, (i.e., the register goes back to initial status.)
Operating Procedure
Condition: Any time, outside or during any operation sequence except during Key Setting or
Key Location Changing {Chapter 13) or System Option Setting.
Operation:
X
Use the S Key to turn the
I
Depress the following Numeric Key according to the display and print format for zero
amount:
Numeric Key
Zero-amount
Format
ss
0 0 0
•
mn]
0
•
for use in US or Canada
1
Depress the
key.
An All Memory Clear receipt is issued.
All Memory Clear Symbol Line
(39 for Numeric 39, or 19 for Numeric 19)
Receipt Consecutive No. is res^
to 0001.
(Date and Time remain unreset)
Thank you
Call again
1 1.- 1 Z - 9 3
3 9 * a o 0 ■
0
0
0.1
1 3 - 0 4
1 t - l Z - 9 3
Zero-amount Dispiay & Print Format designated herer
NOTES 1. When the AH Memory Clear is operated, the condition '‘after all sales data
reset” is obtained, just as “Status Clear” or “Sales Memory Clear”. Therefore,
no Reset Reports need to be taken for starting any programming operation.
2. In addition to clearing all memory data, the standard keyboard is automatically
set (refer to Chapter 9 . Keyboard).