MODULEX EXT 321, 481, 641, 802, 962, 1123 BOILERS

Installation, Operation & Maintenance Manual

Table 3-3: Starter Pieces

Boiler Models

Diameter

Material

Kit Part Number

EXT321, 481, 641

4” Diameter

Stainless Steel

Contact vent manufacturer directly

Polypropylene

Contact vent manufacturer directly

PVC

P/N 49051 (included)

EXT 802, 962, 1123

6” Diameter

Stainless Steel

Contact vent manufacturer directly

Polypropylene

Contact vent manufacturer directly

PVC

P/N 49050 (included)

Figure 3-24: Flue Exhaust Diameter Reduction Adaptor Kit and Parts

The flue venting pipe is affixed to the adapter using RTV liquid silicone and then clamped with a
worm-driven Hose Clamp.

When using non-metallic (plastic) venting materials, use Schedule 40 or thicker, Single-wall,
uninsulated pipes. When using non-metallic (plastic) vent systems for Canadian installations,

European to
American
Standard Flue
Adapter

OMM-0087_0E

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

Page 47 of 148

GF-143

Phone: 800-526-0288

12/01/14